摘要 目的评价一种利用磁性压榨式吻合技术(magnetic compressive anastomosis,MCA)完成腹腔大血管吻合的新型血管吻合器。方法实验杂种犬16只按照下腔静脉吻合方式不同随机分为磁压榨吻合技术(MCA)组与手工缝合组,比较MCA与手工缝合技术吻合下腔静脉(inferior vena cava,IVC)的效果,观察2组吻合时间、术中吻合口渗漏血情况、术后彩色多普勒超声、血管造影与组织学检查观察吻合口血流及并发症情况。结果MCA组血管吻合耗时(3.2±1.2)min较手工缝合组(13.2±2.3)min短(P=0.000);MCA组术中吻合口无渗漏血发生,手工缝合组有5例出现吻合口渗漏血;血管x线造影与彩色多普勒超声检查显示MCA组吻合口血流通畅,无狭窄及血栓形成;手工缝合组术后1~6周时共发现3例吻合口轻度狭窄。MCA组较手工缝合组血管壁各层有较好衔接,内皮细胞层光滑,无明显增生,血管腔无异物残留,吻合口炎性反应轻微。结论新型磁性吻合环及磁吻合技术提供了一种简单、快速、吻合效果可靠的血管吻合方法,MCA血管吻合术可减少由于传统缝合技术与材料导致的吻合口并发症。 Objective To evaluate the magnetic pinned-ring device for non-suture vascular anastomosis in dogs. Methods Sixteen adult mongrel dogs of either gender were randomly divided into two gnoups for IVC in situ end-to-end anastomosis: group MCA (n = 8 ) using magnetic rings for IVC reconstruction, and hand-sewing group ( n = 8 ). Operation time and anastomotie leaking were recorded. Patency and stoma stenosis was evaluated by color Doppler ultrasound scanning, X-ray cholangiography and histological examination at different time points as late as 6 weeks after surgery. Results The time required to perform the vascular anastomosis was significantly shorter for the magnetic device ( 3.2 ±1.2 ) min than for hand sewing ( 13.2 ± 2. 3 ) min (P = 0. 000). Anastomotie leaking occurred in 5 dogs in hand- sewing anastomosis group. Vascular X-ray angiography and color Doppler ultrasound identified normal blood flow in magnetic anastomosis group, and no stoma stenosis, while there were 3 stoma stenosis in the manual suture group. Magnetic ring device stoma is superior to manual suturing in smooth re-endothelialization, less fibrotie collagen deposition and depressed infiltration of inflammatory cells at the anastomotie site. Conclusions The magnetic ring device offers a simple, fast, reliable, and efficacious technique for nonsuture vascular anastomosis with satisfactory prognosis.
出处 《中华普通外科杂志》 CSCD 北大核心 2013年第12期931-934,共4页 Chinese Journal of General Surgery
基金 国家自然科学重点基金资助项目(30830099)
关键词 吻合术 外科 下腔静脉 磁压榨吻合技术 Anastomsis, surgical Inferior vena cava Magnetic compression anastomosis
  • 相关文献

参考文献7

  • 1Schwarz B, Pomaroli A, Hoermann C, el al. Liver transplantation without venovenous bypass: morbidity and mortality in patients with greater than 50% reduction in cardiac output after vena cava clamping. J Cardiothorac Vasc Anesth ,2001,15 :460-462.
  • 2Pagnanelli DM, Pait TG, Rizzoli HV, et al. Scanning electron micrographie study of vascular lesions caused by mierovascular needles and suture. J Neurosurg, 1980,53:32-36.
  • 3Lidman D, Lyczakowski T, Daniel RK. The morphology and patency of arterial and venous microvascular anastomoses throughout the first post-operative year. A histological study. Scand J Plast Reconstr Surg, 1984,18 : 187-192.
  • 4Persin LS, Markov BP, Titov VI, et al. The use of pelxnanent magnets in the orthodontic clinic. Stomatologiia (Mosk) , 1995, 74:76-78.
  • 5朱永锋,王立强,杨平,覃继宁,吕维洁,张荻.β钛合金研究进展及其在骨科中的应用前景[J].生物骨科材料与临床研究,2011,8(4):25-28. 被引量:17
  • 6Bloemen A, van Dooren P, Huizinga BF, et al. Randomized clinical trial comparing polypropylene or polydioxanone for midline abdominal wall closure. Br J Surg,2011,98 :633-639.
  • 7李飞,贾国良,张荣庆,刘兵,赵新国.弱恒磁场对人脐静脉及兔主动脉内皮细胞增殖的影响[J].中国病理生理杂志,2003,19(6):772-772. 被引量:21

二级参考文献37

  • 1于振涛,周廉,罗丽娟,牛金龙,王立新,袁思波,皇甫强,张亚锋.新型近β型医用钛合金TLM的加工、组织与性能[J].稀有金属,2006,30(2):226-230. 被引量:18
  • 2Wang K. The use of titanium for medical application in the USA [J]. Mated Sci Eng, 1996, A213 : 134-137.
  • 3Buly R L.Titanium wear debris in failed cemented total hip arthroplasty[J]. J Arthroplasty, 1992,7(3) : 315-323.
  • 4Zwicker R, Buenler K, Mueller R, et al. Mechanical properties and tissue reactions of a titanium alloy for implant materials[A]. Titaniums' s 80 Science and Technology. Warrendale, PA:TMS-AIME, 1980, 505-514.
  • 5Semlitsch M,Staub F, Webber H. Titanium-aluminum-niobium alloy, development for biocompatible, high strength surgical implants[J], Biomed Techik, 1985, 30 : 334-339.
  • 6Semlitsch M, Webber H, Streicher R, et al. Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy [J].Biomaterials, 1992,13(11):781-788.
  • 7Laheurte P, Eberhardt A, Philippe MJ. Influence of the microstructure on the pseudoelasticity of a metastable beta titanium alloy[J]. Mater Sci Eng A, 2005, 396 : 223-230.
  • 8Ying LZ, Niinomi M, Akahori T. Decomposition ofmartensite during aging treatments and resulting mechanical properties of Ti-Ta alloys[J]. Mater Sci Eng A, 2004, 384 : 92-101.
  • 9Yang GJ, Zhang T. Phase Transformation and Mechanical Properties of the Ti50-Zr30-Nb10-Ta10 Alloy with Low Modulus and Biocompatible[J].Journal of Alloy and Compound, 2005, 392 : 291-294.
  • 10Yu SY, Scully JR. Corrosion and passivity of Ti-13Nb-13Zr in comparison to other biomedical implant alloys [J]. Corrosion J, 1997, 53(12) : 965-976.

共引文献34

同被引文献41

引证文献5

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部