期刊文献+

均流器均匀排风的实验研究

Experimental Study on Homogeneous Air Exhaust by Equalizer
原文传递
导出
摘要 本文应用测压管测压原理,设计了两种形式的排风均流器,并利用实验系统进行了多种工况的均匀排风实验。实验表明单独采用单面阀均流器不能实现均匀排风,而采用单面阀均流器加传统风阀和双面阀均流器调节方式都可以实现均匀排风,且后者的调节方式耗能小,节省占地面积。均流器均匀排风的距离远长于常规风阀均匀排风的送风距离。 According to the pressure measuring principle, two types of equalizer for air exhaust have been designed. The experiment on the prototype of equalizer is conducted. The experiment results show that the equalizer with single side valve for air exhaust is not used alone to achieve uniform exhaust and using these two means, joint use of the equalizer with single side valve and traditional valve and using of the equalizer with double side valves are able to achieve uniform exhaust. The latter approach has less energy consumption and less occupation area. The distance of air exhaust by equalizers is much farther than that by air valve.
出处 《建筑科学》 北大核心 2013年第12期81-86,共6页 Building Science
关键词 排风均流器 均匀排风 排风距离 equalizer for air exhaust, Homogeneous air exhaust, distance of air exhaust
  • 相关文献

参考文献3

二级参考文献6

  • 1匿名著者,棉纺织技术,1989年,8期
  • 2陆耀庆,供暖通风设计手册,1987年
  • 3魏润柏,通风工程空气流动理论,1987年
  • 4匿名著者,纺织厂空气调节,1980年
  • 5匿名著者,棉纺织技术,1978年,12期
  • 6匿名著者,棉纺织技术,1977年,9期

共引文献13