摘要 换热器管束在使用过程中,由于各种原因会造成腐蚀穿孔,引起介质泄漏,因此需要进行定期检验。针对换热器管束的检验,提出了在用换热器铁磁性钢管的远场涡流检测技术,主要包括远场涡流检测原理、探头选择、试样制备、检测仪器及操作条件等。最后通过现场检测和对缺陷的解剖验证,表明该方法能快速、有效地实现换热器管束的检测,并有助于准确评估换热管的使用寿命,以便及时采取措施,保证装置的安全运行。 The tube bundle of the heat exchanger may encounter corrosion perforation due to different causes in the service,leading to leakage of the medium. In order to avoid the occurrence of any leakage accident,regular inspections of the tube bundle are required. The method of remote field eddy current tests is presented for regular inspections of the inservice ferro-magnetic heat exchanger tubes. According to the conditions of field tests,the theory of remote field eddy current testing,the detector,the testing instrument and the suggested testing rules are shown. By investigating the site application and anatomizing the defects,it is shown that the method is fast and effective. It is helpful to evaluate the service life of a heat-exchanger tubing accurately,so that measures can be taken in time to ensure the safe operation of the devices.
出处 《管道技术与设备》 CAS 2013年第6期17-19,32,共4页 Pipeline Technique and Equipment
基金 国家质检总局科技计划项目(2010QK210)
关键词 远场涡流检测 铁磁性 换热器 remote field eddy current test ferro-magnetic heat exchanger
  • 相关文献

参考文献4

  • 1SCHMIDT T R. History of the remote field eddy current inspection technique[J].{H}Materials Evaluation,1989,(01):5-8.
  • 2SCHMIDT T R. The remote field eddy current inspection technique[J].{H}Materials Evaluation,1984,(02):20-24.
  • 3任吉林.电磁无损检测[M]{H}北京:航空工业出版社,198946-65.
  • 4廉纪祥,沈跃.管道远场涡流检测技术的进展[J].油气储运,2004,23(7):14-16. 被引量:28

二级参考文献3

  • 1[1]Schmidt T R: History of the remote field eddy current inspection technique, Materials Evaluation, 1989,47 (1).
  • 2[2]Schmidt T R: The remote field eddy current inspection technique,Materials Evaluation, 1984,42(2).
  • 3[3]Sun Y S and Lord W:Finite-element study of diffusion energy flow in low-frequency eddy current fields, Materials Evaluation,1989,47(1).

共引文献27

同被引文献40

  • 1林俊明,任吉林,徐可北.涡流检测.北京:机械工业出版社,2013.
  • 2MIX P E.Introduction to nondestructive testing-A training guide. Wiley Interscience, 2005.
  • 3KOBAYASHI N, UENO S,NAGAI S, et al. Remote field ed- dy current testing for steam generator inspection of fast reac- tor. Nuclear Engineering Design, 2011 (2) : 4643-4648.
  • 4MARTIN J G, GIL J G,VAZQUEZ-SANCHEZ E.Non-Destruc- tire Techniques Based on Eddy Current Testing. Sensors, 2011 (11) :2525-2565.
  • 5SCHMIDT T R. The remote field eddy current inspection tech- nique. Materials Evaluation, 1984(2) : 225-230.
  • 6MACLEAN W R. Apparatus for magnetically measuring thick- ness of ferrous pipe:The United States of America, 2573799. 1951-11-06.
  • 7SCHMIDT T R.The casing inspection tool--an instrument for the in-situ detection of external casing corrosion in oil wells. Corrosion, 1961 (7) : 81- 85.
  • 8ATHERTON D L, SULLIVAN S.The remote field through wall electromagnetic inspeetion technique for pressure pipes. Materials Evaluation, 1986 (3) : 1544-1550.
  • 9FISHER, CAIN S T. Remote field eddy current model de- velopment. 16th NDE Symposium, San Antonio, 1986.
  • 10PALANISAMY R. Theoretical prediction of remote field ed- dy current response for the nondestructive evaluation of me- tallic tubes. Journal of Applied Physics, 1987 (8) :3202- 3204.

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部