期刊文献+

螺旋桨成像在诊断急性脑梗死中的价值 被引量:2

下载PDF
导出
摘要 目的探讨螺旋桨成像(PROPELLER)在诊断急性脑梗死中的应用价值。方法选取158例临床疑诊急性脑梗死的患者分别行PROPELLER和磁共振扩散加权成像(DWI)检查。结果 158例患者中,脑梗死87例(脑干梗死11例),这87例脑梗死患者中33例存在伪影,15例为昏迷引起的运动伪影,18例为金属异物或颅骨引起的磁敏感伪影;33例中常规EPI DWI在颞叶、额叶、脑干和小脑出现伪影,采用PROPELLER FSE DWI均显著消除伪影的影响;PROPELLERFSEDWI检出全部93个急性脑梗死灶,常规EPIDWI检出81个,漏诊12个。结论采用PROPELLERFSEDWI技术明显消除患者因运动或金属异物造成的伪影,改善图像质量,提高病灶的检出率。
机构地区 丽水市人民医院
出处 《现代实用医学》 2013年第12期1341-1342,共2页 Modern Practical Medicine
  • 相关文献

参考文献6

  • 1Van Everdingen K J, Van der Grond J, Ka- ppelle LJ, et al. Diffusion-weighted mag- netic resonance imaging in stroke[J]. Stroke, 1998(29): 1783-1790.
  • 2冯衍秋,陈武凡,黄鑫,陈阳.磁共振成像PROPELLER采样数据重建中的运动估计新算法[J].中国生物医学工程学报,2007,26(3):361-367. 被引量:4
  • 3戈明媚,王秋良,刘志钦,刘晓林,廖玉珍,孙玮,孙楠,张英魁.MR螺旋桨扫描技术在消除伪影方面的临床应用[J].中华放射学杂志,2006,40(2):208-212. 被引量:37
  • 4Pipe JG. Motion correction with PRO- PELLER MRI: application to head motion and free-breathing cardiac imaging[J].Magn Reson Med, 1999, 42(5): 963-969.
  • 5Forbes KP, Pipe JG, Bird CR, et al. PROPELUR MRI, clinical testing of a novel technique for quantification and compensation of head motion[J]. Magn Reson Med, 2001, 14(3): 215-222.
  • 6Forbes KP, Pipe JP. Improved image quality and detection of acute cerebral in- farction with PROPELLER diffusion weighted imaging MR imaging[J]. Radiology, 2002, 225(2):551-555.

二级参考文献19

  • 1侯正松,江贵平,王华峰,陈武凡.MR图像刚性平移运动伪影的自动逆向迭代修正[J].中国生物医学工程学报,2004,23(4):353-358. 被引量:9
  • 2Nishimura DG,Irarrazabal P,Meyer CH.A velocity k-space analysis of flow effects in echo-planar and spiral imaging.Magn Reson Med,1995,33:549-556.
  • 3Glover GH,Pauly JM.Projection reconstruction techniques for reduction of motion effects in MRI.Magn Reson Med,1992,28:275-289.
  • 4Meyer CH,Hu BS,Nishimura DG,et al.Fast spiral coronary artery imaging.Magn Reson Med,1992,28:202-213.
  • 5Ehman R,Felmlee J.Adaptive technique for high-definition MR imaging of moving structures.Radiology,1989,173:255-263.
  • 6Ordidge RJ,Helpern JA,Qing ZX,et al.Correction of motional artifacts in diffusion-weighted MR images using navigator echoes.Magn Reson Imaging,1994,12:455-460.
  • 7Sachs T,Meyer CH,Irarrazabal P,et al.The diminishing variance algorithm for real-time reduction of motion artifacts in MRI.Magn Reson Med,1995,34:412-422.
  • 8Pipe JG.Motion correction with PROPELLER MRI:application to head motion and free-breathing cardiac imaging.Magn Reson Med,1999,42:963-969.
  • 9Ehman RL,Felmlee JP.Adaptive technique for high-definition MR imaging of moving structures[J].Radiology,1989,173:255-263.
  • 10McGee KP,Grimm RC,Felmlee JP,et al.The shoulder:adaptive motion correction of MR images[J].Radiology,1997,205:541-545.

共引文献36

同被引文献17

  • 1Mahmoud OM, Tominaga A, Amatya VJ, et al. Role of PROPELLER diffusion weighted imaging and apparent diffusion coefficient in the diagnosis of sellar and parasellar lesions[J]. Eur J Radiol. 2010. Jun 74(3):420- 427.
  • 2Mahmoud OM, Tominaga A, Amatya VJ, et alo Role of PROPELLER diffusion-weighted imaging and apparent diffusion coefficient in the evaluation of pituitary adenomas[l]. Eur J Radiol. 201. Nov 80(2):412-417.
  • 3Sabry A. E1 Mogy, Jehan A. Mazroa, Mahmoud hbd E1 Ghaffar, et alo Evaluation of acquired cholesteatoma with PROPELLER diffusion imaging[J]. The Egyptian Journal of Radiology and Nuclear Medicine .2011. 42:9-17.
  • 4Omar M. Mahmoud, Atsushi Tominaga, Wishwa Jeet Amatya, et alo Role of PROPELLER diffusion-weighted imaging and apparent diffusion coefficient in the evaluation of pituitary adenomas[J]. European Journal of Radiology. 2011.80: 412-417.
  • 5X. Chen, J. Xian, X. Wang Role of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging in correcting distortion and evaluating head and neck masses using 3 T MRI[J]. Clinical Radiology. 2014.69:403-409.
  • 6钱根年,陈自谦,倪萍.螺旋桨技术消除颅脑磁共振图像伪影的临床价值探讨[J].医疗卫生装备,2010,31(2):76-78. 被引量:10
  • 7汪桦,吴文娟,于向荣,张威江,王德杭.磁共振Propeller技术在颅脑MR成像中的临床应用价值[J].江苏医药,2010,36(18):2137-2139. 被引量:2
  • 8郑建刚,梅莉,许建兴,刘良卿,周鸿雁,顾勇坚.刀锋伪影校正技术在头部运动伪影纠正的应用[J].中国医学计算机成像杂志,2010,16(6):539-543. 被引量:2
  • 9魏强,宋清伟,刘义军.Propeller技术消除头部磁共振伪影的应用[J].中国医药导报,2011,8(17):188-189. 被引量:3
  • 10陈玉林,吴力源,胡晓云,陆艳艳,翟晓东,夏震,陈静雯,方向明,陈宏伟.刀锋伪影校正技术在颅脑高场MRI中的临床应用价值[J].中国现代医学杂志,2011,21(23):2929-2931. 被引量:5