期刊文献+

关注自动化体液细胞检测及质量控制 被引量:6

Pay attention to the automated body fluid cytology analysis and quality control
原文传递
导出
摘要 近来,自动化体液细胞分析技术逐渐走向临床实验室,检测速度和精密度的提高,克服了传统镜检法费时费力及重复性差等缺点。为充分发挥自动化体液细胞分析技术的优势,需通过复检规则,将其与镜检法有机地结合起来;同时,需关注标本采集和保存、仪器性能验证及必要的临床沟通。通过加强体液细胞检测的质量管理、检测标准化、报告分析和解释等环节,真正发挥体液细胞学检查的临床重要作用。 Automated body fluid cytology analysis has been accepted by clinical laboratories gradually. The improvement of efficacy and analytical precision can overcome some defects of traditional manual method, such as time-consuming and poor repeatability. To make use of the advantages of automated fluid cell analysis technology, the automated method and microscopic method must be combined by setting review rules. Meanwhile, more attentions must be paied to sample collection and specimen preservation at pre-analytical stage, verification of instrument performance at analytical stage and necessary clinical communication at post-analytical stage. Only if a complete system of quality management, standardization of procedures, result validation and interpretation is implemented in the routine work, the clinical significance of body fluid cytological analysis can be recognized in clinical practice.
作者 崔巍 杜娟
出处 《中华检验医学杂志》 CAS CSCD 北大核心 2013年第12期1057-1059,共3页 Chinese Journal of Laboratory Medicine
关键词 体液 细胞学技术 自动化 质量控制 Body fluids Cytological techniques Automation Quality control
  • 相关文献

参考文献6

二级参考文献32

  • 1许良中.临床肿瘤细胞学研究的历史回顾与展望[J].癌症,2004,23(12):1717-1720. 被引量:9
  • 2姜傥,张式鸿,胡伟,钟武平,苏肖丽,蔡丹.一种新型尿液检测模式的探讨及其软件研究[J].中华检验医学杂志,2006,29(7):608-611. 被引量:29
  • 3孙兰青,吴茅.122例胸腹水非特异性炎症标本细胞图文报告分析[J].浙江临床医学,2006,8(11):1216-1216. 被引量:4
  • 4Barnes PW,McFadden SL,Machin SJ,et al.The international consensus group for hematology review:suggested criteria for action following automated CBC and WBC differential analysis.Lab Hematol,2005,11:83-90.
  • 5Bourner G,Dhaliwal J,Sumner J.Performance evaluation of the latest fully automated hematology analyzer in a large commercial laboratory setting:a 4-way,side-by-side study.Lab Hematol,2005,11:285-297.
  • 6熊立凡,刘成玉.临床检验基础.4版.北京:人民卫生出版社.2008:139-144.
  • 7dos Santos JC,Weber LP,Perez LR.Evaluation of urinalysis parameters to predict urinary-tract infection.Braz J Infect Dis,2007,11:479-481.
  • 8Delanghe J.New screening diagnostic techniques in urinalysis.Acta Clin Belg,2007,62:155-161.
  • 9Mayo S,Acevedo D,Quinones-Torrelo C,et al.Clinical laboratory automated urinalysis:comparison among automated microscopy,flow cytometry,two test strips analyzers,and manual microscopic examination of the urine sediments.J Clin Lab Anal,2008,22:262-270.