期刊文献+

200MW褐煤机组改烧烟煤的试验研究

Experimental Study of a 200 MW Boiler Unit Undergoing a Change of Combustion Fuel from Brown Coal to Bituminous One
下载PDF
导出
摘要 20 0MW褐煤机组在改为全烧烟煤时 ,进行了改前改后的对比性试验 ,试验中发现 ,在设备不做大的改动时 ,可全烧省内烟煤。锅炉效率基本达到烧褐煤时的设计值 ,燃烧稳定。 130MW以上不需投油助燃 ,未发现结焦 ,炉膛平均温度水平略高于烧褐煤时的温度。煤粉细度高于经济煤粉细度 ,磨出口温度高、含氧量高 。 A contrast test has been conducted to identify the changes that may occur after a 200 MW boiler unit operating on brown coal turned to firing only bituminous coal. During the test it is found that without making major equipment changes the boiler unit under discussion can operate wholly on bituminous coal of Heilongjiang Province. In such a case the boiler has an efficiency basically equivalent to the design efficiency it will attain when operating on brown coal and also a stable combustion at that. At a load in excess of 130 MW the boiler unit can maintain its stable combustion without the use of oil. Meanwhile, no slagging has been detected and the furnace average temperature found to be a little higher than in the case of firing brown coal. Moreover, the fineness of the pulverized coal appears to be higher than that needed for economic combustion. It is also noted that a high temperature coupled with a high oxygen content of the pulverized coal at mill outlet may lead to an inability to meet the explosion proof requirements of the pulverized coal preparation system.
出处 《热能动力工程》 EI CAS CSCD 北大核心 2000年第6期647-651,共5页 Journal of Engineering for Thermal Energy and Power
关键词 褐煤 试验 燃煤锅炉 brown coal, bituminous coal, boiler efficiency, combustion adjustment, pulverized coal preparation system
  • 相关文献

参考文献1

  • 1岑可法,锅炉燃烧试验研究方法及测量技术,1992年

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部