期刊文献+

生活饮用水硫化物测定余氯干扰消除方法 被引量:1

Removal of residual chlorine interference in determination of sulfide in drinking water
原文传递
导出
摘要 目的建立生活饮用水硫化物测定中余氯干扰的消除方法。方法选用盐酸羟胺消除水中余氯干扰,改进方法在准确度、检出限、精密度及稳定性等方面均适用于生活饮用水中硫化物的准确测定。结果盐酸羟胺可以消除水中余氯干扰,测定波长665 nm,显色时间10 min,稳定时间90 min,回归方程A=0.0736c+0.0233,r=0.9999,最低检测质量0.04μg,低、中、高三种浓度加标回收率分别为100%、101%和98%,相应的RSD值为6.7%、6.3%和4.1%,精密度分别为2.9%、3.5%和3.3%。结论该方法在生活饮用水硫化物测定中,盐酸羟铵能有效地去除余氯的干扰,方法回收率高,准确可靠。 Objective To eliminate the interference of residual chlorine in the determination of sulfide in drinking water. Methods Hydmxylamine hydrochloride was selected to eliminate residual chlorine interference. The improved method was suit- able for accurate determination of sulfide in drinking water in accuracy, detection limit, precision and stability. Results Hy- droxylamine hydrochloride can eliminate the residual chlorine interference at detection wavelength of 665nm, color- developed time of 10 min, stable time of 90 min. The regression equation was A = 0. 0736c + 0. 0233, r = 0. 9999. The lowest detection limit was O. 04 μg. The recovery rates were 100% , 101% and 98% , respectively, the corresponding RSDs were 6.7% , 6.3% and 4.1% , and the precision were 2.9% , 3.5% and 3.3%, respectively at low, medium and high concentrations. Conclu- sion This method can effectively remove the interference of residual chlorine without influencing the determination of sulfide with high recovery and accuracy.
出处 《中国卫生检验杂志》 北大核心 2013年第18期3489-3491,共3页 Chinese Journal of Health Laboratory Technology
关键词 生活饮用水 硫化物 余氯 Drinking water Sulfide Residual chlorine
  • 相关文献

参考文献5

二级参考文献25

共引文献33

同被引文献4

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部