从电力系统无功优化潮流新概念的思路出发 ,提出了变电所无功补偿容量设计的新方法。推行这种基于经济压差 (△UJ)原理的无功补偿容量设计和运行的新方法 ,必将逐步改进我国无功电源或无功补偿的布局 ,提高无功补偿容量的利用率 ,降低工程造价 ,电网的高线损和电压质量状况也将根本改善。
From thinking way of new concept for reactive optimization of power system a new method for design of reactive compensated capacity of substation has been brought up.Carrying out this new method for design and operation of reactive compensated capacity based on the principle of economic pressure difference (△ U J) will gradually improve the layout of reactive power source and reactive compensation in China,increase the availability of reactive compensated capacity,reduce the engineering cost and basically improve the high line loss of the power network and conditions of voltage quality. [
出处
《电力建设》
北大核心
2001年第1期13-15,共3页
Electric Power Construction
关键词
变电所
无功补偿容量设计
新方法
电力系统
潮流
substation
reactive compensated capacity
new method
reactive optimization tide
economic pressure difference