摘要
本文首先建立了测试室动态热工系统的仿真模型,然后分析了变水量和变风量调节方式下该模型动态响应特性;最后,针对FFSI和CRI模糊控制方法,进行了测试室动态热工系统模糊控制的仿真研究。结果表明,调节方式不同,测试室系统动态响应特性也不同,且FFSI法较CRI法的控制仿真效果好。
In this paper,firstly the simulating model for the dynamical thermal system of testing room has been founded. Secondly, the dynamical response characteristics of the model have been analyzed with various adjusting methods variable water volume and variable air volume.Thirdly,simulating studies of fuzzy control have been carried out for the dynamical thermal system of testing room performs various dynamical response characteristics in various adjusting methods,and the method of FFSI has better simulating control effect than CRI.
出处
《制冷学报》
CAS
CSCD
北大核心
1999年第4期18-26, ,共9页
Journal of Refrigeration
基金
国家和黑龙江省杰出青年科学基金!( 批准号:59625815)
关键词
测试室动态热工系统
控制仿真
模糊
暖通空调
dynamical thermal system of testing room adjusting method dynamical response characteristic functioning fuzzy subset inference fuzzy control simulation