摘要
以实验室自制阳离子聚丙烯酰胺P(AM—DAC)为样品,分别用沉淀滴定法和胶体滴定法对其阳离子度进行测定,并用数理统计方法对2种方法进行分析比较,实验结果表明,沉淀滴定法和胶体滴定法都可以准确测定产品的FEl离子度,但胶体滴定法比沉淀滴定法更具有稳定性和准确性。实验还研究了不同滴定因素对胶体滴定法的影响,表明PH值在1.75~2.25范围内,滴定速度在0.01~0.05mL/S范围内,滴定溶液质量浓度选在1×10-4~2×10-4g/mL范围内,所测定的阳离子度最接近于理论值。
The precipitation titration method and colloid titration method are respectively used to determine the cationic degree of cationic polyacrylamides P (AM-DAC) samples that are self-prepared in the laboratory. And mathematical method is used to comparatively analyze the two methods. It is found that both precipitation titration and colloid titration can accurately measure cationic degree, but the colloid titration method is more stable and accurate than precipitation titration method. The influence of different factors on the colloid titration are also analyzed in experiments, and the experimental results show that the measured value of cationic degree is the closest to the theoretical value when the pH value is within the range of 1.75 to 2.2, the titration rate in the range of 0.01 mL/s to 0.05 mL/s, and the titrimetric solution concentration in the range of 1×10-4~2×10-4g/mL.
出处
《重庆大学学报(自然科学版)》
EI
CAS
CSCD
北大核心
2014年第1期110-116,共7页
Journal of Chongqing University
基金
国家自然科学基金资助项目(21177164
51078366)
教育部高等学校科技创新工程重大项目培育基金资助项目(708071)
关键词
水处理剂
聚丙烯酰胺
PEl离子度
测定
胶体滴定法
water treatment chemicals
polyacrylamide
cationic degree
determination
colloid titration