期刊文献+

基于eQUEST能耗模拟的某办公楼空调方案分析 被引量:6

Energy Saving Analysis of Air Conditioning System for One Office Building based on eQUEST Simulation
下载PDF
导出
摘要 以夏热冬暖地区某办公楼为研究对象,利用eQUEST能耗模拟软件计算得到全年逐时空调负荷,对比模拟分析了三种常见空调方案的运行能耗和经济性。结果表明:对于夏热冬暖地区,办公建筑采用VRV变频多联机系统分别比冷源均为水冷螺杆机的全空气系统及风机盘管加新风系统节能5.4%和1.2%,其静态投资回收期分别比后两者缩短3.9年和0.49年。节能和经济效益均十分明显。 The hourly air conditioning load of an office building in hot summer and warm winter zone was simulated with eQUEST tool. Energy consumptions of the three commonly used air conditioning systems were compared, and some meaningful conclusions were reached. It is found that VRV inverter multi-line system performs better than air system and fan-coil system, with energy saving potential of 5.4% and 1.2% respectively. The static payback period can also be shortened by 3.9 years and 0.49 years, separately. All these implies that VRV inverter multi-line system preserves specular advantages in energy saving and economic effect.
出处 《建筑热能通风空调》 2013年第5期56-58,5,共4页 Building Energy & Environment
关键词 夏热冬暖地区 办公建筑 空调方案 节能分析 hot summer and warm winter zone, office building, air conditioning system, energy saving analysis
  • 相关文献

参考文献6

  • 1清华大学建筑节能研究中心.中国建筑节能年度发展研究报告[M].北京:中国建筑工业出版社,2009.
  • 2张炜伟.福州市区机关办公建筑能耗调查与分析[J].能源与环境,2009(3):38-40. 被引量:4
  • 3公共建筑节能设计标准(GB50189-2005)[S].
  • 4徐秋生,陈启,许爱民.多联机空调系统设计探讨[J].暖通空调,2008,38(1):69-73. 被引量:17
  • 5彭芝军,桂苗苗.厦门市大型公共建筑能耗统计分析[J].燃气与热力,2011,31f4):21.23.
  • 6陆耀庆.实用供热空调设计手册[M].北京:中国建筑工业出版社,1994..

二级参考文献2

共引文献61

同被引文献30

引证文献6

二级引证文献33