期刊文献+

中空纤维超滤膜纯水通量测定的不确定度评定 被引量:1

EVALUATION OF UNCERTAINTY IN MEASUREMENT OF PURE WATER FLUX OF HOLLOW FIBER ULTRAFILTRATION MEMBRANE
原文传递
导出
摘要 纯水通量代表超滤膜的生产能力,是超滤膜重要的表征参数之一。测定了聚偏氟乙烯中空纤维超滤膜的纯水通量,建立了纯水通量测定不确定分析数学模型。根据《测量不确定度评定与表示》中相关规定,运用不确定度传递原理评定了测量结果的不确定度。结果表明,该方法测量结果不确定度的主要来源是纯水通量重复性测量和测试水温。当超滤膜样品纯水通量为1.02×10-1 m3/(m2·h)时,测定结果的扩展不确定度为1.04×10-2 m3/(m2·h)。 Pure water flux is one of the most important characterization parameters of ultrafiltration membrane, which directly represents the membrane production capacity. The pure water flux of hollow fiber ultrafiltration membrane was determined and the mathematical model for uncertainty assessment was established. According to Evaluation and Expression of Uncertainty in Measurement and the principle of error transfer, the components of the uncertainty in the measurement of pure water flux of hollow fiber ultrafiltration membrane were analyzed. The uncertainty of this method was mainly caused by replicate determination and the temperature of the pure water. The expanded uncertainty was 1.04×10^-2m^3/(m^2·h) as the pure water flux of hoUow fiber ultrafiltration membrane was 1.02×10^-2m^3/(m^2·h).
出处 《水处理技术》 CAS CSCD 北大核心 2014年第3期53-56,共4页 Technology of Water Treatment
基金 国家海洋公益性行业科研专项项目(201105025) 中央级公益性科研院所基本科研业务费专项资金项目(K-JBYWF-2011-T04)
关键词 超滤膜 纯水通量 不确定度 ultrafiltration membrane pure water flux uncertainty
  • 相关文献

参考文献8

二级参考文献69

共引文献92

同被引文献7

引证文献1

二级引证文献3