期刊文献+

干燥方法和试件尺寸对加气混凝土等温吸湿曲线的影响 被引量:7

Effect of Drying Methods and Sample Sizes on Moisture Absorption Isotherms of Aerated Concrete
下载PDF
导出
摘要 采用干燥剂法、70℃烘干法和105℃烘干法处理了2种尺寸(4cm×4cm×2cm和3cm×3cm×1cm)的加气混凝土试件,比较了3种干燥方法得到的试件干重差异.用静态称重法测定了70℃烘干的大小试件在不同相对湿度下的平衡含湿量,并用统计学方法进行比较,然后采用Peleg模型拟合了加气混凝土等温吸湿曲线.结果表明:70℃烘干法得到的试件干重比干燥剂法得到的试件干重多0.13%~0.16%,而105℃烘干法得到的试件干重比干燥剂法得到的试件干重少1.02%~1.06%.大小加气混凝土试件在相同相对湿度下的平衡含湿量并不相等,在中高相对湿度下小试件的平衡含湿量明显较小.不同干燥条件下大小加气混凝土试件拟合等温吸湿曲线有明显差异.在测试加气混凝土等温吸湿曲线时,推荐采用70℃烘干大试件. Aerated concrete samples of two sizes(4 cm×4 cm×2 cmand 3 cm×3 cm×1 cm) were dried with desiccant at room temperature and with oven at 70 ℃ and 105 ℃ respectively. The dry masses ob- tained from different drying methods were compared. Static gravimetric method was used to obtain the e- quilibrium moisture contents in samples dried in oven at 70 ℃ in different relative humidities, and a statis- tical comparison was made. Peleg model was used to fit the moisture absorption isotherms of aerated con- crete. Results reveal that the dry mass obtained from oven drying method at 70℃ is 0.13%-0.16% grea- ter than that obtained from desiccant drying method at room temperature, while oven drying method at 105 ℃ gives 1.02%- 1.06% smaller dry mass. Moreover, the equilibrium moisture contents in samples of different sizes under the same relative humidity are not the same. In middle-high relative humidity range, the equilibrium moisture contents in smaller samples are noticeably less. The fitted moisture absorption i- sotherms of samples with different sizes and drying methods are noticeably different. The one for bigger sample dried in oven at 70 ℃ is recommended as the moisture absorption isotherm of aerated concrete.
出处 《建筑材料学报》 EI CAS CSCD 北大核心 2014年第1期132-137,142,共7页 Journal of Building Materials
基金 "十二五"国家科技支撑计划项目(2011BAJ01B01)
关键词 加气混凝土 干燥方法 试件尺寸 干重 平衡含湿量 等温吸湿曲线 aerated concrete drying method sample size dry mass equilibrium moisture content mois-ture absorption isotherm
  • 相关文献

参考文献29

  • 1SCHEFFLER G, GRUNEWALD J, PLAGGE R. Evaluation of functional approaches to describe the moisture diffusivity of building materials[J]. Journal of ASTM International, 2007,4 (2) :1-16.
  • 2PAZERA M,SALONVAARA M. Multilayer test method for water vapor transmission testing of construction materials [J]. Journal of Building Physics, 2012,35 (3) : 224-237.
  • 3SWIRSKA-PERKOWSKA J. Estimation of moisture superfi- cial diffusivity in porous materials[J]. International Journal of Heat and Mass Transfer,2011,54(1/2/3) : 692-697.
  • 4YU S,BOMBERG M,ZHANG X. Integrated methodology for evaluation of energy performance of the building enclosures (Part 4) : Material characterization for input to hygrothermal models[J]. Journal of Building Physics, 2012,35 (3) : 194-212.
  • 5CARMELIET J,DEROME D. Temperature driven inward va- por diffusion under constant and cyclic loading in small-scale wall assemblies(Part 1):Experimental investigation[J]. Buil- ding and Environment, 2012,48 (1) : 48-56.
  • 6VEREECKEN E,ROELS S,JANSSEN H. In situ determina- tion of the moisture buffer potential of room enclosures[J]. Journal of Building Physics,2011,34(3) ,223-246.
  • 7van BELLEOHEM M, STEEMAN M, WILLOCKX A, et al. Benchmark experiments for moisture transfer modelling in air and porous materials[J]. Building and Environment, 2011,46 (4) ,884-898.
  • 8ISO 12571:2000(E) Hygrothermal performance of building materials and products:Determination of hygroscopic sorption properties[S].
  • 9ASTM E96-00 Standard test method for water vapor trans- mission of materials[S].
  • 10裴清清,陈在康.几种常用建材的等温吸放湿线试验研究[J].湖南大学学报(自然科学版),1999,26(4):96-99. 被引量:22