过热器复合柠檬酸清洗可行性分析 被引量:5

Practicability of solving superheater oxides by chemical cleaning using recombination citric acid
下载PDF
导出
摘要 对锅炉过热器化学清洗存在的技术难点进行了剖析,指出过热器化学清洗存在氧化皮难溶解、腐蚀控制、垂直弯管易堵塞等难点。对此,研发了复合柠檬酸化学清洗配方及工艺。该工艺清洗剂可快速溶解氧化皮,剥离量小,不堵塞U型或W型管,金属腐蚀速度小,对过热器系统无不利影响,使得过热器化学清洗具有可行性。 The technical difficulties of chemical cleaning were analyzed, such as insoluble ferric oxides, corrosion controlling and blockage in vertical bend tube. Thus, the composition and technique of chemical cleaning using recombination citric acid was developed. This cleaning solvent can dissolve oxides scale rapidly with little exfoliation and no blockage in U-type or W-type tubes. Moreover,it has extremely low corrosion rate on metal,and has no bad effect on the super heating system. Thus,chemical cleaning for superheaters is feasib
出处 《热力发电》 CAS 北大核心 2014年第3期101-103,共3页 Thermal Power Generation
关键词 过热器 化学清洗 柠檬酸 氧化皮 腐蚀 堵塞 superheater chemical cleaning citric acid ferric oxides seale corrosion blockage
  • 相关文献

参考文献8

二级参考文献22

  • 1陈超,庄文军,张祥金,胡家元.过热器管道化学清洗试验研究[J].热力发电,2013,42(1):67-72. 被引量:15
  • 2李耀君.氧化皮脱落导致的过热器管爆管分析[J].热力发电,2005,34(6):56-59. 被引量:29
  • 3银龙,宋寿春,毕法森,何洪利.超临界机组氧化皮的产生与防范[J].电力设备,2006,7(10):33-36. 被引量:29
  • 4于志勇,钱州亥,刘金生,庞胜林.超超临界机组的EDTA化学清洗[J].中国电力,2007,40(7):25-28. 被引量:6
  • 5唐海宁,等.2000t/h锅炉高温过热器氧化皮形成剥离机理分析与综合治理[A].首届江苏省电力安全论文集,2004.
  • 6DL/T794-2012.火力发电厂锅炉化学清洗导则[S].
  • 7GB/T228.1-2010金属材料拉伸试验第1部分:室温试验方法[S].
  • 8JEREMY B, ARTHUR T Motta. Oxidation behavior of ferritie- martensitie and ODS steels in supertritieal water[J]. Journal of Nuclear Materials. 2012. 424:261-276.
  • 9FRY A, OSGERBY S, WRIGHT M. Oxidation of alloys in steam environments-A review[R]. NPI, Materials Centre, 2002:28-33.
  • 10OWEN W D, MARTIN S. Smfaee complexation and dissolution of hematite by CI-C6 diearboxylie acids [J]. Ge(Jchinfiea el Cosmoehimiea Aeta, 2001,65(23):4289-4301.