摘要 为得到Trichel脉冲放电的特征,采用针-板电极结构对空气中负电晕放电的特性进行了实验研究。利用示波器测试了放电电压、电流波形和脉冲频率,利用微安表测试了平均放电电流,并通过放电结构上并联电容的方法研究了外接电容对放电的影响。结果表明,空气负电晕Trichel脉冲非常稳定、规则;其脉冲频率随平均电流线性增大,针尖曲率影响频率上升的斜率,但电极间距、气压、并联电容对频率影响较小;不同放电条件下的Trichel脉冲波形基本相同,其上升沿几乎不随电流、间距、气压、针尖曲率和并联电容变化,但脉冲幅值随平均电流略有下降,同时与间距、气压、针尖曲率和并联电容等条件有关;Trichel脉冲是电晕区的特征放电,在给定电极条件下,其形成过程与平均电流(电压)、气压和外电路并联电容等无关。 In order to obtain some characteristics of Trichel pulses, we experimentally investigated negative corona in air using a needle-to-plate electrode. We measured the frequency, current, and discharge voltage of Trichel pulses using digi- tal oscilloscope, and average discharge current using micro-amperemeter. Through connecting capacitance in parallel to the discharge structure, we also investigated the influence of external capacitance on the discharge. The results show that the negative-corona Trichel pulses are stable and regular: their pulse frequency increases linearly with averaged current with a speed influenced by the tip radius of needle node, but it is barely influenced by the gap length, the air pressure, and the capacitance in parallel. The pulses also have the same current waveform under different conditions: their rising time hardly changes with the averaged current, the gap length, the air pressure, the tip radius, or the capacitance, and their am- plitude is influenced slightly by the averaged current as well as the other discharge conditions. It is concluded that Trichel pulses are characteristic discharge in corona region, and with a given electrode pair, their generation process is indepen- dent of discharge current, gas pressure, and external circuit.
出处 《高电压技术》 EI CAS CSCD 北大核心 2014年第4期1194-1200,共7页 High Voltage Engineering
基金 机电动态控制国家重点实验室基金(2011C3606)~~
关键词 针-板电极 电晕放电 负电晕 Trichel脉冲 脉冲电流 上升沿 脉冲频率 needle-to-plate configuration corona discharge negative corona Trichel pulse pulsed current rising time repetition frequency
  • 相关文献

参考文献23

  • 1Golden M, Golden A. Corona discharges: gaseous electronics (Chap 4)[M]. Hirsh M and Oskam H J ed. New York, USA: Academic Press Inc., 1978.
  • 2Trichel G W. The mechanism of negative point to plane corona near onset[J]. Physical Review, 1938, 54(12): 1078-1084.
  • 3Loeb L B, Kip A F, Hudson G G Pulses in negative point-to-plane corona[J]. Physical Review, 1941, 60(10): 714-722.
  • 4Loeb L B. The mechanism of the trichel pulses of short time duration in air[J]. Physical Review, 1952, 86: 256-527.
  • 5Lama W L, Gallo C F. Systematic study of the electrical characteristics of the Trichel current pulses from negative needle-to-plane coronas[J].Journal Applied Physics, 1974, 45(1): 103-13.
  • 6Shang K F, Xue X X, Wang X C. Tfichel pulse characteristics in nega- tive dc corona discharge[C]//Proceedings of 2011 Asia-Pacific Power and Energy Engineering Conference. Wuhan, China: IEEE, 2011: 4-7.
  • 7He S J, Ha J, Han Y H, et al. Tfichel pulses in a negative corona dis- charge in air at low pressure[J]. Journal of Physics: Conference Series, 2013, 418(1): 012091.
  • 8Morrow R. Theory of stepped pulses in negative corona discharges[J]. Physical Review A, 1985, 32(6): 3821-3824.
  • 9Morrow R. Theory of negative corona in oxygen[J]. Physical Review A, 1985, 32(3): 1799-1809.
  • 10Sofia C, Pontiga F, Castellanos A. Particle-in-cell simulation of elec- trical gas discharges[J]. Journal of Computational Physics, 2001, 171: 47-78.

二级参考文献24

  • 1林晓宇,陈仕修,张晓敏.高压输电线路电晕放电电磁辐射影响分析[J].电力环境保护,2004,20(3):60-62. 被引量:26
  • 2林晓宇,陈仕修,谢齐家,夏长征,孙幼林.金具电晕辐射特性的实验研究[J].高压电器,2004,40(6):407-408. 被引量:7
  • 3张海峰,庞其昌,陈秀春.高压电晕放电特征及其检测[J].电测与仪表,2006,43(2):6-8. 被引量:85
  • 4隋晓杰,宋守信.高压输电线路电晕放电分析[J].电力建设,2006,27(3):37-38. 被引量:40
  • 5Raizer Yu P. Gas discharge physics[M]. Berlin, Germany:Springer-Verlag, 1991.
  • 6Golden M, Golden A. Corona discharge[M]. New York, USA: Academic Press Inc,1978.
  • 7Lai K X,Phung B T, Blackburn T R, et al. Separation of corona noise from on-line partial discharge monitoring of power ca-bles[C]//International Conference on Condition Monitoring and Diagnosis. Piscataway, NJ,USA: [s. n. ], 2008: 1270-1274.
  • 8Cheng Yangchun,Li Chengrong,Huang Xingquan. Study of corona discharge pattern on high voltage transmission lines for inspecting faulty porcelain insulators [J]. IEEE Transactions on Power Delivery, 2008,23(4) : 945-952.
  • 9Kawada M, Tungkanawanich A, Kawasaki I,et al. Detection of wide - band E-M signals emitted from partial discharge occurring in GIS using wavelet transform[J]. IEEE Transactions on Power Delivery, 2000, 15(2) : 467-471.
  • 10Tungkanawanich A, Kawasaki I,Abe J , et al. Location of partial discharge source on distribution line by measuring emitted pulse-train electromagnetic waves [C] // IEEE Power Engineering Society Winter Meeting. Piscataway, NJ, USA: IEEE, 2000: 2453-2458.

共引文献12

同被引文献367

引证文献15

二级引证文献130

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部