期刊文献+

Reciproc系统预备弯曲根管的体外研究 被引量:1

EXTRACORPORAL STUDY ON CURVED ROOTCANAL PREPARED WITH RECIPROC SYSTEM
下载PDF
导出
摘要 目的观察Reciproc系统预备弯曲根管的成形效果。方法选择40例弯曲根管作为实验对象,根管预备前插入初尖锉拍摄颊舌向及近远中向标准化X线片,预备后采用同一角度插入主尖锉拍摄标准化X线片,通过对预备前后根管偏移情况进行比较评价Reciproc系统的成形效果。结果 Reciproc系统预备弯曲根管后未发生器械折断、变形,未发生根管偏移,预备时间短,成形效果好。结论 Reciproc单根锉预备弯曲根管能保持原有根管形态,且预备效率较高,使用较安全。
作者 廖志夫
出处 《现代医院》 2014年第4期49-50,共2页 Modern Hospitals
  • 相关文献

参考文献7

  • 1陈炯,褚敏,梁景平.两种镍钛机动器械根管预备的比较研究[J].牙体牙髓牙周病学杂志,2005,15(4):202-204. 被引量:11
  • 2YARED G. Canal preparationusingonlyoneNi - Ti mtaryinstru- ment: preliminary observations [ J ]. Int Endod J, 2008,41 ( 4 ) :339 -344.
  • 3FRANCO V, FABIANI C,TASCH1ERI S,et al. Investigation on the shaping ability of nickel - titanium files when used with a recipro- catilag motion[ J ]. J Endod ,2011,37 (10) :1398 - 1401.
  • 4PURIFICACION V P,ADALCEI P,BERTA R M,et al. Alternat- ingversuscontinuousrotation :acomparativestudyof theeffect onlnstnl- ment Life[J]. J Endod ,2010,36( 1 ) :157 -159.
  • 5BURKLEIN S, HINSCHITZA K, DAMMASCHKE T, et al. Shaping ability and cleaning effectiveness of two single - file systems in se- verely curved root canals of extracted teeth : Reciproc and WaveOne versus Mtwo and ProTaper[ J ]. Im Endod J, 2012,45 (5) :449 - 461.
  • 6林正梅,凌均棨,高燕,秦伟.两种镍钛机动预备器械根管清理效果的电镜观察[J].中山大学学报(医学科学版),2005,26(6):707-710. 被引量:15
  • 7陈文平.改进口腔诊疗器械消毒技术操作流程[J].现代医院,2013,13(10):96-99. 被引量:9

二级参考文献29

  • 1黄少宏.口腔科感染管理[J].中国感染控制杂志,2006,5(4):357-359. 被引量:22
  • 2黄少宏.广东省口腔医疗机构无菌技术应用情况调查研究[J].中国自然医学杂志,2006,8(4):250-252. 被引量:2
  • 3黄少宏.广东省口腔诊疗器械消毒灭菌质量调查报告[J].中国消毒学杂志,2007,24(3):258-260. 被引量:4
  • 4Short JA, Morgan LA, Baumgartner JC. A comparison of canal centering ability of four instrumentation techniques [ J ]. J Endod, 1997,23 ( 8 ) :503 - 507.
  • 5Bergmans L, Van Cleynenbreugel J, Wevers M, et al. Mechanical root canal preparation with Niti rotary instruments:rationale, performance and safety. Status report for the American Journal of Denstistry[ J] .Am J Dent,2001,14(5) :324 -333.
  • 6Bramante CM, Berbert A, Borges RP. A methodology for evaluation of root canal instrumentation [ J ]. J Endod, 1987,13 ( 5 ):243 - 245.
  • 7Coleman CL, Svec TA, Rieger MR, et al. Analysis of nickel - titanium versus stainless steel instrumentation by means of direct digital imaging [ J ]. J Endod, 1996,22 ( 11 ): 603 - 607.
  • 8Jeon IS,Spangberg LS, Yoon TC, et al. Smear layer production by 3 rotary reamers with different cutting blade designs in straight root canals:A scanning electron microscopic study [ J ]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod,2003,96( 5 ) :601 -607.
  • 9Gonzalez - Rodriguez MP, Ferrer- Luque CM. A comparison of Profile, Hero 642 and K3 instrumenta6on systems in teeth using digital imaging analysis [ J ]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod ,2004,97 ( 1 ): 112 - 115.
  • 10Peters OA, Laib A, Gohring TN, et al. Changes in root canal geometry after preparation assessed by high - resolution computed tomography [ J ]. J Endod,2001,27 ( 1 ): 1 - 6.

共引文献32

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部