期刊文献+

微克质量标准磁性测量中的关键问题

Some key problems of magnetic measurement for micro-gram standards
下载PDF
导出
摘要 砝码的磁性对于砝码质量值测量的影响越来越受到人们的重视.比较了3种磁性测量的方法及磁化率和磁场强度不确定度分量,指出其与微克质量标准磁性测量中的不同,进而提出一个测量弱磁性微克质量标准磁化率的方法.通过砝码磁性参数的测量原理,指出了测量过程中可能影响测量的关键因素,包括湿度、温度、压力、振动、空气中的磁性颗粒,以及待测微克质量标准在磁化率计上的摆放方式. Magnetic interactions between weights may lead to errors in precision mass metrology. In this paper, we compared three methods of magnetic measurement and the uncertainty factors were given out for magnetic susceptibility and magnetic polarization. An analytical description of differences between normal weights and micro- gram standards were presented and then the measurement method for micro-gram standards made of weak magnetic substance was discussed. According to the measurement principle of weight magnetic parameters, the key influence on measurement accuracy is presented in the measurement process, which included humidity, temperature, air pressure, vibration, magnetic granules in the air and place method of micro-gram standards.
出处 《中国计量学院学报》 2014年第1期17-21,27,共6页 Journal of China Jiliang University
基金 国家科技支撑计划项目(No.2011BAK15B06) 国家重大科学仪器设备开发专项(No.2012YQ090208) 中国博士后科学基金面上资助项目(No.2013M541003) 中国计量科学研究院基本科研业务项目(No.AKY1314-13)
关键词 微克质量标准 质量计量 磁性测量 磁化率 磁化强度 micro-gram standards mass metrology magnetic measurement magnetic susceptibility magneticpolarization
  • 相关文献

参考文献16

二级参考文献13

  • 1托马斯费林,托马斯弗勒利希,德特勒夫海登布卢特,王文革(译).砝码件的磁性能检验[J].衡器,2006,35(2):48-50. 被引量:4
  • 2党正强,薛靓.砝码磁性的测量及不确定度分析[J].中国测试技术,2006,32(5):39-41. 被引量:5
  • 3OIMLR111-1,砝码国际建议[S].2004.
  • 4JJGl059-1999,测量不确定度评定与表示[s].北京:中国计量出版社,1999.
  • 5全国质量密度计量技术委员会.JJG99-2006[S].北京:中国计量出版社,2006.
  • 6JJG99—2006《砝码》检定规程.中国计量出版社.
  • 7JJFl059-1999《测量不确定度评定与表示》.中国计量出版社.
  • 8JJG99—2006(砝码》.北京:中国计量出版社,2006.
  • 9JJGl059—1999《测量不确定度评定与表示》.北京:中国计量出版社.1999.
  • 10裴玉洁.天平[M].北京:中国计量出版社,1993.

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部