期刊文献+

PTA结晶器压缩机干气密封故障分析及结构优化

Fault analysis and structure optimization of dry gas seal installed in PTA crystallizer compressor
下载PDF
导出
摘要 分析了PTA结晶器压缩机干气密封泄漏原因,并针对PTA装置工况特点,对干气密封结构进行了优化设计。优化后的密封结构具有较高的抗干扰能力和较长的使用寿命。 The leakage reasons for dry gas seal installed in PTA crystallizer compressor were analyzed. Considering the working conditions in PTA plant,the structure of dry gas seal was optimized. Engineering experiences have proved that the optimized sealing structure can meet the requirements on higher anti-interference ability and longer service life.
作者 严明盛
出处 《聚酯工业》 CAS 2014年第3期54-56,共3页 Polyester Industry
关键词 PTA 压缩机干气密封 优化 PTA compressor dry gas seal optimization
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部