期刊文献+

基于荧光猝灭原理的光纤化学传感器在线监测水中溶解氧 被引量:31

On-line Monitoring of Dissolved Oxygen in Water by a Fiber-optic Chemical Sensor Based on Fluorescence Quenching
下载PDF
导出
摘要 利用氧分子对芘丁酸的荧光具有猝灭作用的特性 ,构造出基于荧光猝灭原理的光纤氧化学传感器。就用于水中溶解氧在线监测的光纤光谱仪的搭建、传感探头的设计及传感膜的制作进行了探索 ,并对传感器的响应性能进行了考察。结果表明以三醋酸纤维素为固相支持剂、邻苯二甲酸二辛酯为增塑稳定剂、芘丁酸为分析物识别器制备的传感膜对溶解氧的响应具有良好的可逆性 ,稳定性 ,较快的响应时间和较长的使用寿命。与标准法相对照 ,用本仪器系统测定了不同盐度的人工海水中的溶解氧浓度 ,两种方法在不同浓度水平下的溶解氧测定值均无显著性差异。本法的日内和日间RSD在 2 4 %~ 6 A novel circulatory system for on\|line monitoring of dissolved oxygen that makes use of a fiber\|optic chemical sensor is presented.An oxygen sensitive optode was combined with a membrane onto which was immobilized pyrenebutyric acid as a fluoroprobe,the membrane was composed of cellulose triacetate as a polymer and di\|(2\|ethyl hexyl)\| o \|phthalate as a plasticizer.The dissolved oxygen in water was determined via quenching of the fluorescence of pyrenebutyric acid.The optode shows a satisfactory linear response for the dissolved oxygen in water( r =0 995?6, n =6).The relative standard deviations were 2 4%~6 1%. The detection limit was 0 03?μg/mL( S/N =3).The exposure time and recovery time of the optode membrane are 5s and 25s respectively.The reversibility of the fluorescence signal was evaluated by alternate measurements in air saturated water and nitrogen\|purged water.The relative standard deviation( n =6)were found to be 0 7%.The fluorescence intensity of the membrane in contact with flowing water was recorded over a period of 96?h.From fluorescence intensity values taken every 4?h( n =24)a RSD of 8% was obtained.After 3 month,the fluorescence signal of the membrane had decreased by 14%.The decrease may be due to washing out of fluoroprobe,but this was not an obstacle to its further use;the quantitative information( F 0/ F )did not change significantly,where F 0 and F are the fluorescence intensities in the absence and in the presence of oxygen,respectively.The sensor has good reproducibility and long\|term stability.The interference was investigated and the selectivity of method in seawater was affirmed by a conventional method.
出处 《北京大学学报(自然科学版)》 CAS CSCD 北大核心 2001年第2期226-230,共5页 Acta Scientiarum Naturalium Universitatis Pekinensis
基金 国家"九五"科技攻关 !(96 A2 3 0 2 0 8) 国家"八六三"高技术计划海洋领域 !(818 Q 0 9)资助项目
关键词 光导纤维 化学传感器 氧传感器 溶解氧 荧光猝灭 在线监测 人工海水 fiber optic chemical sensors oxygen sensor dissolved oxygen
  • 相关文献

参考文献7

  • 1Chan M A,Lawless J L,Lam S K,et al.Fiber Optic Oxygen Sensor Based on Phosphorescence Quenching of Erythrosine B Trapped inSilica-gel Glasses.Anal Chim Acta,2000,408:33~37
  • 2Choi M M F,Xiao D.Single Standard Calibration for An Optical Oxygen Sensor Based onLuminescence Quenching of A Ruthenium Complex.Anal Chim Acta,2000,403:57~65
  • 3Chuang H,Arnold M A.Linear Calibration Function for Optical Oxygen Sensors Based onQuenching of Ruthenium Fluorescence.Anal Chim Acta,1998,368:83~89
  • 4Ishiji T,Kaneko M.Photoluminescence of Pyrenebutyric Acid Incorporated intoSilicone Film as A Technique in Luminescent Oxygen Sensing.Analyst,1995,120:1 633~1 638
  • 5陈坚,李伟,阎超,袁立懋,郭炬亮,周新继.基于多猝灭响应原理的PBA光纤化学膜传感器的性能和应用研究[J].中国科学(C辑),1997,27(1):69-75. 被引量:24
  • 6Li W,Chen J.Continuous In-vivo Monitoring of Metronidazole in Cerebrospinal Fluidby A On-line Flow-cell Fiber-optic Chemical Sensor System.Anal Chim Acta,1996,331:103~109
  • 7国家技术监督局.中华人民共和国国家标准GB12763.4-91,1991:11-138

二级参考文献10

  • 1陈坚,药物分析杂志,1995年,15卷,411页
  • 2李伟,药学学报,1995年,30卷,599页
  • 3朱滨,Anal Chim Acta,1994年,292卷,311页
  • 4陈坚,分析科学学报,1994年,10卷,31页
  • 5陈坚,新疆医学院学报,1994年,17卷,162页
  • 6陈坚,新疆医学院学报,1994年,17卷,255页
  • 7朱滨,药学学报,1994年,29卷,369页
  • 8陈坚,新疆医学院学报,1993年,16卷,85页
  • 9陈坚,传感技术学报,1992年,5卷,34页
  • 10陈坚,Anal Chim Acta,1990年,237卷,265页

共引文献23

同被引文献784

引证文献31

二级引证文献150

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部