摘要
采用价廉的涤纶滤膜作为电解体系隔膜,利用阴、阳极同时作用降解含酚工业废水,在反应时间80min,曝气量1.2L/min,电流密度30mA/cm2的最佳条件下,含酚废水COD去除率可达到80%,阴极室COD去除率高于阳极室。
This paper studies electro-catalytic oxidation of phenol wastewater using inexpensive polyester membrane as a electrolytic diaphragm system with anode and cathode functioning simul-taneously.The optimum conditions of wastewater treatment are determined as follows:the cur-rent density is 30 mA/cm2 ,aeration rate is 1.2 L/min,electrolysis time is 80 min.Under these conditions,the removal rates of COD could reach 80%.