期刊文献+

血清氟测定标准方法的验证及应用 被引量:5

Verification and application of standard method for detecting serum fluoride
下载PDF
导出
摘要 目的 在氟研究科研课题中应用 GBW氟标准物质验证血清氟测定标准方法 ,评价其实用价值。方法 用 GBW标准物质对 ISE-标准曲线 ,标准添加法 ,线性范围 ,线性关系 ,灵敏度 ,精密度进行校验 ,并对 40 0余份大鼠血清进行测定。结果 该方法的线性范围 :氟离子浓度为 0 .0 2~ 5 .0 m g/ L、 r=0 .9999、b=5 7.8,检测下限为 0 .0 13m g/ L,标准物质的测定值与标准值相符。结论 该测定方法准确、灵敏 ,样品用量小 (仅 0 .4ml) ,操作简便 ,易于推广 ,具有实际应用价值。 Objective Standard method of testing serum fluoride was tested and verified by certified reference material CRM of free fluoride component in cattle serum (GBW 09143~09144).The method was suited for fluoride research to assess its practical value.Methods ISE standard curve,linear relationship,linear range,sensitive and precision were disired result by CRM.400 serum of fluoride in rats were measured.Results The linear ranges of the method were 0.02~5.0 mg/L,r=0.9999,b=57.8,and test lower limit was 0.013 mg/L.The test value was equal to standard value.Conclusions The standard method is accurate,sensitive,convenient and small sample is used;and it is easy to spread.Thus,it has been of practical value.
出处 《中国地方病学杂志》 CAS CSCD 北大核心 2001年第2期140-142,共3页 Chinese Jouranl of Endemiology
关键词 标准方法 验证 应用 血清诊断 氟中毒 Fluoride Standard method Verification Application
  • 相关文献

参考文献7

二级参考文献41

共引文献84

同被引文献12

  • 1叶平,边建朝,杨瑞康,刘源,史乃捷.牛血清游离氟成分分析标准物质研制[J].卫生研究,1996,25(1):40-42. 被引量:4
  • 2[6]IKENSHI RIKIO, KITAGAWA TAKAYASU, NISHIUCHI MASANORL, et al. Gas Chromatographic method for the determination of fluoride ion in biological samples I fluoride level in monkey[J]. Chem pharm bull, 1988,36 (2) :662.
  • 3Ikenshi Rikio, Kitagawa Takayasu, Nishiuchi Masanorl, et al.Gas Chromatographic method for the determination of fluoride ion in biological samples.I fluoride level in monkey[J].Chem pharm bull,1988,36(2):662.
  • 4杨惠芬.食品卫生理化检验标准手册[M].北京:中国标准出版社,1998.173-175.
  • 5全浩.标准物质及其应用技术[M].北京:中国标准出版社,1990..
  • 6刘昌汉,主编.地方性氟中毒防治指南[M].北京:人民卫生出版社,1987.159-186.
  • 7WS/T 212-2001,血清中氟化物测定-离子选择电极法[S].
  • 8万桂敏,陈志,张丽虹,刘忠杰.血清或血浆中的氟化物[J].中国地方病防治,2000,15(2):90-92. 被引量:14
  • 9万桂敏,王守智,徐春蓓,于光前,王育文,叶平,张丽虹,张志瑜,石玉霞.血清中无机氟测定标准方法的研究[J].中国地方病防治,2000,15(5):266-269. 被引量:10
  • 10李菊梅,李建国.氟离子选择电极法在测试中应注意的事项[J].理化检验(化学分册),2003,39(2):118-119. 被引量:13