期刊文献+

一种制作头颈肩热塑面膜方法的可行性研究 被引量:1

A study on the feasibility of the new method of making head and shoulder mask
下载PDF
导出
摘要 目的:通过改善头颈肩面膜的制作方法,解决由于面膜收缩给患者带来的不适,同时验证其对放疗位置精度的影响。方法:将需进行头颈肩面膜制作的患者随机分成两组。每组10人,A组患者常规制作面膜,行CT扫描定位;B组患者在制作面膜时在头枕下加垫1.5mm塑料片,取下塑料片后行CT扫描定位。两组病人常规设计放疗计划并行位置验证,分别对比BEV及验证片位置误差。结果:A组患者的X、Y、Z三个方向的摆位误差分别为:2.45±0.59mm,2.64±0.46mm,1.15±0.17mm;B组患者的X、Y、Z三个方向的摆位误差分别为:2.25±0.55mm,2.4±0.40mm,1.17±0.11mm。A、B两组内X、Y、Z做One-way ANOVA分析,其F值分别为12.88和15.31,P值小于0.05,A、B两组内的X、Y、Z有统计学意义。A、B两组间对应X、Y、Z配对t检验,P>0.05,差别无统计学差异。结论:通过头枕下加垫片的方式减少了热塑面膜收缩引起的患者不适,并未降低摆位精度,是一种可行有效的方法。 Objective Through improving the method of making head and shoulder mask, we want to solve the problem that patients often feel discomfort due to the shrinkage of mask, and to verify the effect of position accuracy in radiotherapy. Methods: The patients who need to make head and shoulder mask were randomly divided into two groups. Each group has 10 patients , In the group A , The conventional method are used to make head and shoulder mask and CT scanning; In the group B, 1.5mm plastic sheet is put under the head pillow pad when patients are making mask, and taken off when patients are scanning CT. Then patients in each group are designed conventional radiotherapy planning and verifying position by comparing BEV and iVIEW GT respectively. Results: In the group A the setup error in X, Y, Z were: 2.45 ± 0. 59mm, 2. 64 ± 0. 46mm, 1.15 ± 0. 17mm; in the group B the setup error in X, Y, Z were: 2. 25 ±0. 55mm, 2. 4 ±0.40mm, 1.17 ±0. 11mm. In each group data of the setup error in X, Y, Z were analyzed by One -way ANOVA , the F values were 12. 88 and 15.31 respectively, P 〈0. 05, In each groups the setup error in X, Y, Z had statistical significance. Between A and B group the setup error in X, Y, Z were analyzed by paired t test, P 〉 0.05, no statistical significance difference was found between The three direction respectively. Conclusion: 1.5mm plastic sheet is put under the head pillow pad when patients are making mask and taken off when patients are scanning CT. This is a new approach to make mask. It can reduce the shrinkage of the thermoplastic mask and discomfort of patients. The accuracy of setup is unaffected. The new approach is an effec- tive and feasible method.
出处 《医疗装备》 2014年第6期16-18,共3页 Medical Equipment
关键词 放射疗法 热塑面膜 摆位精度 radiation therapy thermoplastic mask setup accuracy
  • 相关文献

参考文献7

  • 1胡逸民.治疗体位及体位固定技术[A].胡逸民,扬定宇.肿瘤放射治疗技术[M].北京:北京医科大学中国协和医科大学联合出版社,1999.200-205.
  • 2崔广余,秦康,赵燕生,等.影响热塑固定膜收缩率的因素研究[C].首届全国放射治疗技师大会论文集,2005.184-185.
  • 3惠华,张旭光,耿冲,王强,陈宏林,迟振飞,杜傲男.热塑体膜在体位固定中收缩变化规律的研究及结果分析[J].医疗装备,2013,26(1):7-9. 被引量:9
  • 4Bijhold J, van Herk M, Vijlbrief R, et al. Fast evaluation of patient setup during radiotherapy by aligning features in portal and simulator images [ J] . Physmed Biol, 1991, 36 (12) : 1665.
  • 5Stroom JC, de Boer JC, Huizenga H, et al. Inclusion of geometrical uncertain ties in radiotherapy treatment plan- ning by mean s of coverage probability [ J ] . Int J Radiat Oncol Biol phys, 1999, 43 (4) : 905.
  • 6应惟良,叶新芊,吴金明.热塑面膜固定鼻咽癌患者放疗摆位技术的周期误差分析[J].实用癌症杂志,2008,23(5):525-526. 被引量:7
  • 7孙朝阳,王连元.质量保证与质量控制[A].徐燮渊,俞受程.现代肿瘤放射治疗学[M].北京:人民军医出版社,2000.162-169.