期刊文献+

五虎山煤矿1201工作面CO浓度超限原因分析及治理 被引量:8

Analysis and Treatment of CO Concentration Overrun in 1201 Working Face of Wuhushan Mine
下载PDF
导出
摘要 介绍了五虎山煤矿1201工作面CO浓度超限情况并分析了其原因,针对该工作面实际特点,采取了均(增)压防灭火措施进行治理。措施实施后,工作面的回风量稳定在650 m3/min,进风量为673 m3/min,采空区的漏风量控制在20 m3/min左右;工作面的上隅角、尾巷内几乎监测不到CO气体,没有出现因CO超限而影响工作面安全生产;上部煤层的老火区也得到了一定程度的控制。 This paper gave a description of the situation of CO concentration overrun in 1202 working face in Wuhushan CoalMine and analyzed the cause of its overrun, to counter the actual characters of the face, the fire control measures by air pressurebalance was taken in this working face. After the implementation of this fire control measure, the air-return quantity remained in650 m3/min and the air-intake quantity in 673 m3/min, the air leakage in the gob was controlled in about 20 m3/min, CO washardly detected at the upper corner angle and in the tail gate of the face, no CO concentration overrun affected the safe productionin this face; in addition, the old fire areas in the upper seams were under control to a certain extent.
作者 陈明河
出处 《矿业安全与环保》 北大核心 2014年第3期105-108,共4页 Mining Safety & Environmental Protection
关键词 煤炭自燃 CO浓度超限 矿井通风 均压防灭火 spontaneous combustion of coal CO concentration overrun mine ventilation air pressure balance for firecontrol
  • 相关文献

参考文献5

二级参考文献1

  • 1王正辉,陈明河.五虎山矿1001工作面自燃治理研究[R].重庆:煤炭科学研究总院重庆研究院,2010.

共引文献78

同被引文献54

引证文献8

二级引证文献34