摘要
介绍了控温箱—热流计法现场检测围护结构传热系数的特点、仪器设备、原理和检测过程,同时对检测过程中影响传热系数检测的准确度因素进行了分析,并提出了相应的措施。
The paper introduces the features of the heat transfer coefficient of the enclosure strucutre, the equipment, the principle and detection process of the site detection with the temperature-controlled box and heat flow meter method, analyzes the factors affecting the accuracy of the heat transfer coefficient in the detection process, and points out respective measures.
出处
《山西建筑》
2014年第19期210-211,共2页
Shanxi Architecture
关键词
现场检测
传热系数
控温箱-热流计法
影响因素
site detection
heat transfer coefficient
temperature-controlled box and heat flow meter
influential factor