着重介绍了3个炼油厂5套催化裂化装置的红外热象检测的结果,通过对这些结果的分析对比,诊断出各催化两器装置内衬里的状况、故障部位及故障的程度,从而为维修决策提供参考依据。
The results of Infrared imaging detection for 5 sets of FCCU in three refineries are presented. Hasing analysed and compared the rerults, the status inside the lining of reactor-regenerator in FCCU, the degree and position of troubles would be well clear to provide an important basis for maintainces.
出处
《红外技术》
CSCD
1991年第3期45-48,共4页
Infrared Technology
关键词
石油炼制
催化裂化
检测
红外热像
Infrared thermal imaging
Thermal imaging technology
Thermal imaging detector for Petroleum Unit