摘要
本文针对压气机入口喷水方式,探讨了利用水的显热及蒸发潜热对压缩空气进行连续冷却的效果,建立了连续冷却(无级间冷)数学模型,在理论上研究了最大注水量、最佳注水量、以及注水最小压比,分析了相应循环的性能特点。
In accordance with the spraying of water at the entrance of compressor,this paper has probed the effect of successive cooling to the compressive air by use of the obvious and latent heat of water,established the successive-cooling (stepless-cooling)mathematic model,discussed the maximum amount of the pouring water,the optimum amount of the pouring water,and the minimum amount of the pouring water,and also analyzed the characteristics of the corresponding cycle.