期刊文献+

高速高分辨率圆感应同步器测角系统的研究 被引量:2

HIGH SPEED AND HIGH RESOLUTION ANGLE MEASUREMENT SYSTEM
下载PDF
导出
摘要 本文基于新的思路 ,突破纯开环或闭环的模式 ,采用总体开环和数字信号处理部分闭环的方案设计了圆感应同步器测角系统 .讨论了其工作原理、硬件框架、典型电路分析 ,及系统在提高运行速度和减小动态误差方面所采取的措施 .整个系统结构简单 ,并具有较高的跟踪速度。 Based on a new way of whole open loop and signal process part closed loop, the inductosyn angle measurement system is designed, it breaks through the one type of closed loop or open loop mode. This paper explained the system working principle, hard ware frame and the typical circuit analysis, the measure of improving the system track speed and diminishing the dynamic error are also discussed. The system have the well performance of simple structure, high track speed, high precision and working stability.
出处 《光子学报》 EI CAS CSCD 北大核心 2001年第7期897-900,共4页 Acta Photonica Sinica
关键词 圆感应同步器 数显 高速测角 数字信号处理 闭环跟踪 数字测角系统 Inductosyn Digital read out High speed angle measurement Signal process Closed loop track
  • 相关文献

参考文献9

二级参考文献7

  • 1宋现春,李春阳.新型感应同步器微机数显装置[J].制造技术与机床,1996(3):31-33. 被引量:2
  • 2梅景登.数字式传动链误差测量系统介绍[J].机床,1984,(2).
  • 3[1]端木时夏.感应同步器及其数显装置.上海:同济大学出版社,1990。
  • 4[6]Zhang Cheng Rui.Computer-based measuring system of transmissin accuracy of machine tool.SPIE Vo12101,1993.
  • 5[7]Qin Shuren.A new system for measuring dynamic accuracy and data processing of gear cutting machine transmission. Chinese Journal of Mechanical Engineering, Vol.26,No.2,1990.
  • 6曾庆双,中国惯性技术学报,1996年
  • 7戴逸民,频率合成与锁相技术,1995年

共引文献11

同被引文献14

  • 1[2]TI.TMS320LF-LC240xA System and Peripherals.2001
  • 2[4]陶永华.新型PID控制及其应用.北京:机械工业出版社,2003:8-26
  • 3吕百达.强激光的传输与控制[M].国防工业出版社,1995-5..
  • 4Lukesh G, Chandler S, Voelz D. Estimation of laser system pointing performance by use of statistics of return photons[J]. Appl Opt,2000, 39(9):1359-1371.
  • 5Steinvall O. Performance of laser tracking of small targets during turbulence and beam jitter[J]. Opt Eng, 2004, 43(7):1609-1621.
  • 6Deshetler B W, Dillow J D. Suppression of noise in the airborne laser system[C]//Proe of SPIE. 1999, 3706:249-257.
  • 7Filatov Y V, Loukianov D P, Probst R. Dynamic angle measurement by means of a ring laser[J]. Metrologia, 1997, 34(4):343-351.
  • 8X Y J, Y L Q, Bennian, et al. A new high-precision two-dimensional dynamic angle measurement instrument with self-sufficient datum[C]//Proceedings of the International Symposium on Test and Measurement. 2001, 2:1535-1537.
  • 9Aoyama H, Yamazaiki K, Sawabe M. Optical sensor for detecting a position and an inclination[J]. Journal of Manufacturing Science and Engineering-Trans of the ASME , 1995, 118(3):400-405.
  • 10Bae E W, Kim J A, Kim S H, et al. Micro-motion measurement system for milli-structure using diffraction grating[C]//Proc of SPIE.2001, 4190:71-79.

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部