运用一维流体动力学模型对 2 0 0MW核供热堆余热排出系统的余热排出过程进行数值模拟 ,并对该系统的排热能力及其影响因素进行了分析。分析表明 :余热排出系统的空冷器面积和空冷塔高度是影响余热排出能力的主要因素 。
The 200 MW NHR(nuclear heating reactor) RHRS(residual heat removed system) is numerically simulated by one dimension fluid dynamics model. The heat removed ability of 200 MW NHR RHRS and its influencing factors are analyzed. The area of air condenser and the height of air cooling tower in RHRS are the main factors influencing the residual heat removed ability , the height difference between the main heat exchanger and air condenser is the secondary factor.
出处
《原子能科学技术》
EI
CAS
CSCD
2001年第5期436-440,共5页
Atomic Energy Science and Technology
关键词
核供热堆
余热排出系统
自然循环
排热能力
数值计算
nuclear heating reactor
residual heat removed system
natural circulation
ability to remove residual heat