期刊文献+

200MW核供热堆余热排出系统排热能力及其影响因素分析

Heat Removed Ability and Its Influencing Factors Analysis on Residual Heat Removed System of 200 MW Nuclear Heating Reactor
下载PDF
导出
摘要 运用一维流体动力学模型对 2 0 0MW核供热堆余热排出系统的余热排出过程进行数值模拟 ,并对该系统的排热能力及其影响因素进行了分析。分析表明 :余热排出系统的空冷器面积和空冷塔高度是影响余热排出能力的主要因素 。 The 200 MW NHR(nuclear heating reactor) RHRS(residual heat removed system) is numerically simulated by one dimension fluid dynamics model. The heat removed ability of 200 MW NHR RHRS and its influencing factors are analyzed. The area of air condenser and the height of air cooling tower in RHRS are the main factors influencing the residual heat removed ability , the height difference between the main heat exchanger and air condenser is the secondary factor.
出处 《原子能科学技术》 EI CAS CSCD 2001年第5期436-440,共5页 Atomic Energy Science and Technology
关键词 核供热堆 余热排出系统 自然循环 排热能力 数值计算 nuclear heating reactor residual heat removed system natural circulation ability to remove residual heat
  • 相关文献

参考文献2

二级参考文献2

  • 1彭木彰,1992年
  • 2王大中,第四届中国核动力工程学会核能动力学力学会年会论文汇编,1991年

共引文献20