期刊文献+

鲁米诺化学发光熄灭法测定稀土镧的研究 被引量:5

The Quenching of Rare Earth La(Ⅲ) Ion in the Chemiluminescence System of Luminol H 2O 2 Cr(Ⅲ)
下载PDF
导出
摘要 本文研究了稀土La(Ⅲ)对Luminol-H2O2-Cr(Ⅲ)化学发光体系的熄灭效应,在此基础上建立了稀土镧的流动注射化学发光分析法,方法的检出限为4×10-8mol/L;对于2×10-7mol/L稀土镧标准溶液测定的相对标准偏差为3.0%(n=11);线性范围为1.0×10-7—1.0×10-4mol/L;相关系数大于0.9984,该法用于合成样品分析,结果满意。 In this paper, a new chemiluminescence analytical method for the determination of rare earth La(Ⅲ) ion is presented. It is based on the qucnching of La(Ⅲ) ion in the chemiluminescence system of Luminol H 2O 2 Cr(Ⅲ). The detection limit is 4×10 -8 mol/L La. The linear range is 1.0 ×10 -7 - 1.0 ×10 -4 mol/L La, The relative standard deviation is less than 3% (for 2×10 -7 mol/L La n =11). The method developed has been applied to the determination of La(Ⅲ) in synthetic samples.
出处 《光谱实验室》 CAS CSCD 1998年第4期20-22,共3页 Chinese Journal of Spectroscopy Laboratory
关键词 稀土 La(Ⅲ) 流动注射化学发光分析 鲁米诺 镧(Ⅱ) 测定 Rare Earth La(Ⅲ), Flow Injection Chemiluminescence Analysis, Luminol.