摘要
本文从分析洁净厂房的三种主要送风模式着手,指出近年来在我国大量采用的风机过滤器机组(FFU)的模式未必最佳,如果不是根据具体情况合理选择,而是盲目跟从,势必给投资、运行和管理带来负面影响。
This paper analyzed three patterns of clean air supply in large scale of clean rooms. It pointed out that Filter Fan Unit (FFU) pattern adopted widely could not be an optimum in China. It must bring some negative affects on the investment, management and running when it would be only followed without selection in accordance with its specific condition.
出处
《洁净与空调技术》
2001年第4期2-7,共6页
Contamination Control & Air-Conditioning Technology
关键词
洁净室
净化系统
送风模式