期刊文献+

SL3-1型双翻斗雨量传感器翻斗翻转频率比例分析及校准 被引量:7

Research on calibration of SL3-1 Type rain sensor with best flip ratio method
原文传递
导出
摘要 雨量传感器校准工作大多依靠装备保障人员的经验和耐心,难度很大,通过对SL3-1型双翻斗雨量传感器人工模拟降水试验,分析大雨强时上翻斗的翻转频率和计量翻斗的翻转频率及其比例和不同调整方法在不同雨强时对测量值的影响,得出一个定量的快速准确的校准方法,该方法较传统的经验法具有定量、简单、快速、准确的特点。 The calibration of rain sensor mostly depends on the experience and patience of equipment support personnel. It is very difficult. Through the artificial precipitation test of SL3-1 double tipping rain sensor,the turning frequency of the upper tipping bucket and the turnover frequency of the tipping bucket are analyzed when the rain is strong. And its proportion and different adjustment methods have a quantitative and rapid and accurate calibration method for the influence of measured values on different rainfall intensity. This method is more quantitative,simple,rapid and accurate than the traditional empirical method.
作者 王卫东 WANG Weidong(Boshan District Meteorological Bureau,Zibo City,Boshan Shandong,255200)
出处 《自动化与仪器仪表》 2019年第2期168-171,共4页 Automation & Instrumentation
关键词 SL3-1型双翻斗雨量传感器 翻斗翻转频率比例 校准方法 SL3-1 double skip rainfall sensor dump hopper frequency ratio calibration method
  • 相关文献

参考文献7

二级参考文献28

  • 1王子海.漏斗数学模型在雨量传感器中的应用[J].气象水文海洋仪器,2005,22(2):27-29. 被引量:2
  • 2朱乐坤,郑丽春.自动气象站各要素传感器检定结果的不确定度分析[J].应用气象学报,2006,17(5):635-642. 被引量:55
  • 3冯讷敏.雨量仪器综述[J].水利水文自动化,1996(3):1-6. 被引量:12
  • 4JJFl033-2008.计量标准考核规范[S].
  • 5俞卫平,周诗建,王伟,等.地面气象观测规范[M].北京:气象出版社,2003:57-121.
  • 6舒荣军,赵俊华.SL-3型遥测雨量传感器计量误差分析[J].安徽气象,2004(1):25.
  • 7中闲气象局.地面气象观测规范[M].北京:气象出版社,2003:55-57.
  • 8西藏自治隧气象局装备中心计量检定所.JJS1型翻斗式雨麓传感器校准仪现场校准讲义[G].拉萨:西藏自治区气象局.2010.
  • 9中闲气象局监测网络司.气象仪器和观测方法指南.第6版[S].北京:中国气象局,2005:102-103.
  • 10房岩松.自动气象站维修手册[M].山东省气象局,2012:72-73.