摘要
文章介绍了与烟气控制有关的中庭建筑特性 ,分析并讨论了中庭面积、长宽比、体型系数、通透率、开敞系数、开启系数、危险指数等参数 。
This paper illustrated the architectural characters which related to smoke controlling,mainly introduce the parameters of atrium areas, ratio of length and width, figuration factor, leakage ratio, door-opening factor, window-opening factor, and dangerous exponent etc. Further researching needed to clarify the concrete relationship between smoke moving and architectural characters of atrium buildings.
出处
《消防科学与技术》
CAS
2002年第3期8-11,共4页
Fire Science and Technology
基金
国家科技进步重点项目 (98- 0 4 - 0 3)
关键词
中庭
烟气控制
烟气运动
火灾
atrium
smoke cntrolling
architectural characters