摘要
本文通过对脉管内自然对流的数值模拟,讨论了当脉管冷端处在不同方向时,脉管内的自然对流对脉管制冷机性能的影响.数值模拟结果表明,当冷端在下时获得的制冷温度最低;当热端在下并与重力方向成30°时制冷温度最高.结论与实验测量结果定性一致.所做的理论分析对实现脉管制冷机的良好运行有指导意义。
The effect of the natural convection on pulse tube cryocooler performance was numerically investigated when the pulse tube was positioned at different orientations. It is found that when the cold end was positioned at lower place the temperature of the cold end was the lowest. While when the hot end was positioned at lower place, and the intersection angle between the pulse tube and the gravitation was 30 degrees, the cold end temperature reached its maximum. These numerical findings were agreeable with available test data.
出处
《工程热物理学报》
EI
CAS
CSCD
北大核心
2002年第3期271-273,共3页
Journal of Engineering Thermophysics
基金
国家973重点基础研究发展规划资助项目(No.G2000026303)
国防科技重点实验室基金资助项目(No.00JS65.4