摘要
介绍了 SF6 开关电器的 SF6 微水过量的危害 ,影响微水含量主要因素 ,以微水露点温度来测算允许微水含量方法 ,并提出了微水含量采标的建议。
The harmfulness of micro content of water in SF 6 circuit breaker is introduced. It also gives the main factors which affect the micro content of water and presents the method to measure micro content of water by dew point temperature. The suggestion about using standard is proposed.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2002年第5期49-49,54,共2页
High Voltage Engineering
关键词
微水过量
危害
采标
六氟化硫开关电器
SF 6 electrical equipment micro content of water adopting standard