摘要
根据FHD 1型质子磁力仪在实际使用过程中存在的一些问题 ,以及一些用户提出的建议和要求 ,对FHD 1型质子磁力仪的实时时钟、标定方法、通用性与适应性、抗干扰能力方面进行了改进和完善 ,本文对此作介绍。
Measures have been taken to improve the FHD1 type proton magnetometer concerning its real-time clock, calibration method, general applicability and suitability, as well as anti-disturbance capability, as a response to the problems found in its practical use as well as to the suggestions and requirements from users. The present paper describes these improvements.
出处
《地震学刊》
CSCD
2002年第2期28-31,共4页
Journal of Seismology