本文采用模型实验的方法,利用正交表和回归分析方法对等温条件下。无障碍物孔板送风静压箱静压分布规律进行研究,定量地提出静压箱侧壁送风方式和插入管道送风方式下的静压分布规律的经验公式,为提出一套新的设计计算方法提供了理论研究依据,进一步完善了孔板送风理论。
In this paper a model experiment is discussed on influence aspects of static pressure field in obstacle-free plenum at isothermal condition,and experimental equations are given to calculate difference of static pressure in plenum with side air supply,and with inside air duct,and gives theoretic basis to design method of air supply orifice plenum.