期刊文献+

不可逆空气制冷循环的制冷率和制冷系数优化 被引量:6

Optimization of Cooling Load and COP of Irreversible Air Refrigeration Cycles
下载PDF
导出
摘要 用有限时间热力学方法分析恒温热源不可逆空气制冷循环特性 ,在总热导率一定的条件下 ,研究最优制冷率、制冷系数时热导率的最优分配 ,并分析了各种参数对循环特性的影响 ,所得结果对工程制冷系统设计有一定的指导意义。 The theory of finite time thermodynamics is applied to analyze the performance of irreversible air refrigeration cycles in this paper. For the fixed total heat exchanger inventory,the ratio of heat conductance of low-temperature side heat exchanger to that of high-temperature side heat exchanger is optimized for maximizing the cooling load and the coefficient of performance (COP) of the cycles. The influences of various parameters on the characteristic of the cycle are analyzed. The results obtained may provide guidance for the design of practice air refrigeration plants.
机构地区 海军工程大学
出处 《制冷》 2002年第2期1-4,共4页 Refrigeration
基金 国家重点基础研究发展规划资助( 973)项目( G2 0 0 0 0 2 6 30 1)
关键词 有限时间热力学 不可逆空气制冷循环 制冷率 制冷系数 优化 Finite time thermodynamics Refrigerator cycles Heat conductance optimization