期刊文献+

1000MW超超临界机组锅炉运行测试

Operational Testing of 1000 MW Ultra Supercritical Coal-Fired Power Generating Unit
下载PDF
导出
摘要 针对某火力发电厂2号机组的锅炉热效率、NOx排放及空气预热器漏风率进行了测试,检验锅炉能否达到供货商对其提供产品所作的性能保证值。结果显示其锅炉效率和NOx排放量达到性能保证值,但空气预热器的漏风率略高于其保证值。 An operational testing of boiler thermal efficiency,NOxemission and leakage rate of air preheater has been done on a Unit 2 power plant for examining whether the performance of the boiler can achieve the guarantee value of the product provide by the supplier. The results show that the efficiency of the boiler and NOxemission achieve the guarantee value while the leakage rate of air preheater is slightly higher than its guarantee value.
作者 吴浪
出处 《锅炉制造》 2014年第4期5-7,共3页 Boiler Manufacturing
关键词 1000 MW超超临界机组 锅炉效率 NOX排放 空气预热器漏风率 运行测试 1000 MW ultra supercritical unit thermal efficiency NOxemission leakage rate of air preheater operational testing