摘要
In order to evaluate the operational reliability of Japanese FBR (fast breeder reactor) MONJU, frequencies of important intermediate events and equipment failures resulting during reactor automatic trip are predicted using FTA (fault tree analysis) technique for the plant system model. The targeted devices are the following: PHTS (primary heat transport system), SHTS (secondary heat transport system), WS (water and steam system), PPS (plant protection system) and PCS (plant control system). In this paper, the frequency of automatic reactor trips was estimated by extracting and analyzing the important intermediate events and equipment failures covering all the derived fault trees of these systems. The analyses predicted 1.2/RY (reactor year) the value of unplanned shut down frequency by the internal factor of the system. The largest contributed event was function failure of SHTS accounting for 42.6% of total events followed by PHTS with 40.1%. The contribution factor of WS was only 4.4%.