摘要
文中介绍谐波的产生、危害,推导出单调谐滤波器滤波容量的计算公式,给出单调谐滤波器最小安装容量的计算公式,并结合多晶硅企业低压配电系统的谐波问题,对低压用电系统进行分析,提出谐波治理方案,并对谐波治理的效果进行分析。
In this paper, the generation and harm of harmonics are introduced. The calculation formula of filtering capacity of single tuned filter is deduced and the calculation formula of minimum installation capacity of single tuned filter is given.The low voltage power system is analyzed with combination of harmonics of low voltage distribution system of polysilicon enterprises, the harmonic control solution is proposed and result of such harmonic control is analyzed.
出处
《电力电容器与无功补偿》
2014年第4期49-52,57,共5页
Power Capacitor & Reactive Power Compensation
关键词
单调谐滤波器
无功补偿
谐波
基波
滤波电容器
滤波电抗器
single tuned filter
reactive power compensation
harmonic
fundamental wave
filter capacitor
filter reactor