期刊文献+

浙江岛屿深井地震台防雷接地系统设计

Design of lightning protection and grounding system for the islands of Zhejiang deep seismic stations
下载PDF
导出
摘要 针对当前岛屿深井地震台设备容易遭雷击及维修不便等问题,通过对雷电入侵台站设备的途径分析,依据现有防雷技术规范和相关理论,对观测房和井口防雷接地采用法拉第笼结构预防雷击,加强接地等电位连接,规范各种线路布设,综合多级雷电防护措施,使岛屿深井地震台站稳定可靠运行。 For the problems that the deep-well seismic equipment on the islands is easily struck by lightning and difficult to be repaired conveniently,with the analysis on the path of lightning intruding the stations equipment and the existant technology on lightning protection and relevant theories,we suggest applying Faraday cage structure to the observation room and the wellhead to prevent lightning,strengthening the grounding equipotential bonding,specifying various line layout and integrating multi-stage lightning protection measures,in order to make sure the deep-well seismic stations on the islands work steadily and reliably.
机构地区 浙江省地震局
出处 《地震地磁观测与研究》 2014年第3期220-224,共5页 Seismological and Geomagnetic Observation and Research
基金 浙江省地震局局科技项目(2013ZJJ01)资助
关键词 深井地震台 防雷系统 法拉第笼 等电位连接 deep seismic station lightning protection system faraday cage equipotential bonding