摘要 采用积分安培-离子色谱法同时测定地下水中的溴离子和碘离子,该方法的相关性好( r>0.999),精密度高(RSD%<4.0),样品加标回收率为90~110%,溴离子检出限为5.6μg/L ,碘离子检出限为2.1μg/L。本法简便、快速、准确且选择性好,可用于分析地下水中的溴离子和碘离子。 A method for determination of bromine and iodine ions in groundwater by ion chromatogra-phy with integrated amperometric detector was studied in this paper .It has good relativity (r〉0 .999) and high precision (RSD% 〈4 .0) .The average recoveries of samples were 90% -110% ,the detection limit of bromine ion was 5 .6μg/L and iodine ion was 2 .1μg/L .This method is simple ,rapid ,exact and has good selectivity ,being suitable for detection of bromine and iodine ions in groundwater .
作者 张飞 韩翠杰
出处 《资源调查与环境》 2014年第3期231-234,共4页 Resources Survey & Environment
基金 国家重大科学仪器开发专项应用方法开发项目(2011Y17006505)资助
关键词 积分安培-离子色谱法 地下水 溴离子 碘离子 integrated amperometric-ion chromatography groundwater bromine ions iodine ions