期刊文献+

基于复眼透镜的大面积均匀照明方案研究 被引量:16

Design and analysis on large area uniform illumination with fly-eye lens
下载PDF
导出
摘要 为了实现大面积矩形均匀光斑,提出一种基于双排复眼透镜的设计方案。使用TracePro软件对该照明系统方案的效果进行建模仿真,分析了复眼透镜组的间距、后工作距离等参数对光斑面积和均匀性的影响。结果表明,复眼透镜间距越小、后工作距离越大,得到的光斑面积越大;而当间距控制在微透镜焦距附近时,光斑均匀性最佳。利用该设计方案,可在1m的后工作距离得到尺寸350mm×200mm的光斑,光斑中心280mm×160mm范围内光照度均匀性>0.85,该部分面积超过光斑整体面积的60%。该匀光方案有望在医用光疗、路灯照明等大面积均匀光照明领域得到广泛应用。 A design with two parallel fly-eye lens arrays was proposed,in order to achieve a uniform rectangular light spot of large area.TracePro simulation was used to analyze the impact of the parameters,such as the space between two fly-eye lens and the back working distance of the optical system,on the size and uniformity of the light spot.The simulations indicates that the smaller the distance between the two lens and the longer the working distance,the larger the formed spot size.The best uniformity of light spot is obtained when the space between the two fly-eye lens is close to the focal length of the first lens.In one design,a spot with size350mm×200mm was obtained on the target plane,which was 1maway from the light source.In the central region of the spot,a range of 280mm×160mm,which covered more than 60%of the total area,produced a light illumination uniformity higher than 85%.This design is expected to be used in medical phototherapy,street lighting,and many other fields.
出处 《应用光学》 CAS CSCD 北大核心 2014年第5期771-778,共8页 Journal of Applied Optics
基金 江苏省自然基金项目(BK2012628) 国家国际科技合作专项(2012DFR10610 2014DFA10590)
关键词 均匀照明 复眼透镜 大面积 矩形光斑 容错性 uniform illumination compound eye lens large area rectangular light spot fault tolerance
  • 相关文献

同被引文献108

引证文献16

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部