双源双能量CT肺动脉成像辐射剂量与图像质量的比较研究 被引量:13

Comparison of radiation dose and image quality of CT pulmonary angiography using dual-source dual-energy CT
下载PDF
导出
摘要 目的:比较第一代双源双能量CT(DECT)与第二代双源双能量CT肺动脉成像(CTPA)的辐射剂量和图像质量。方法:120例疑似肺栓塞患者行DE-CTPA检查,其中40例患者行第二代双源DECT 80/Sn140kV检查(第一组),40例患者行第二代双源DECT 100/Sn140kV检查(第二组),40例患者行第一代双源DECT 140/80kV检查(第三组)。测量每例患者肺动脉主干、肺动脉段、空气及背部脂肪的CT值及标准差,对肺动脉图像进行主观评分,计算图像信噪比(SNR)、对比噪声比(CNR)及每例患者的有效剂量(ED)。结果:第一组肺动脉平均CT值[(354.1±73.4)HU]明显高于第二组[(290.1±73.1)HU,P<0.001]和第三组[(303.9±73.3)HU,P<0.001],但第二组与第三组差异无统计学意义(P=0.399);第三组平均SNR(24.8±8.4)低于第一组(40.4±12.9,P<0.001)和第二组(44.6±12.9,P<0.001),但第一组与第二组差异无统计学意义(P=0.115)。第一组平均CNR(435.3±77.7)明显高于第二组(355.8±77.8,P<0.001)和第三组(384.8±79.0,P=0.005),但第二组与第三组差异无统计学意义(P=0.100)。三组图像主观质量评分差异无统计学意义(P>0.05)。第一组的ED[(1.2±0.3)mSv]明显低于第二组[(2.4±0.7)mSv]和第三组[(3.0±0.7)mSv],差异均有统计学意义(P<0.05)。结论:第二代双源DECT 80/Sn140kV扫描方案可在大幅度降低辐射剂量的同时获得满足诊断需求的图像。 To compare radiation dose and image quality of CT pulmonary angiography (CTPA)using first generation and second-generation dual-source dual-energy CT (DECT).Methods:A total of 120 patients (40 in each group) underwent CTPA on a dual-source CT scanner (group 1:second generation DECT,40 patients,80/Sn140 kV;group 2:sec-ond generation DECT,40 patients,100/Sn140kV;group 3,first generation DECT,40 patients,140/80kV).The mean CT at-tenuations and standard deviations (SD)of main pulmonary,pulmonary arteries,the air,and the fat of the back at the level of the pulmonary trunk were measured.CT value,signal to noise ratio (SNR),contrast to noise ratio (CNR),and effective dose (ED)of pulmonary artery images were compared.Results:The CT values in the pulmonary arteries were significantly higher in group 1 [(354.1 ±73.4)HU,P〈0.001]than those in group 2 [(290.1 ±73.1 )HU,P〈0.001 ]and group 3 [(303.9±73.3)HU,P〈0.001 ];however,no difference was found in CT values between groups 2 and 3 (P=0.399). Mean SNR were lower in group 3 (24.8 ±8.4)than group 1 (40.4 ±12.9,P〈0.001 )and group 2 (44.6 ±12.9,P〈0.001),however,no difference was found for SNR between groups 1 and 2 (P=0.115).Mean CNR were significantly high-er in group 1 (435.3±77.7)than group 2 (355.8±77.8,P〈0.001)and group 3 (384.8±79.0,P=0.005),however,no difference was found for CNR between groups 2 and 3 (P=0.1).Mean ED were the lowest (P〈0.001)in group 1.Conclu-sion:Second generation dual-source DECT with 80/Sn140 kV protocols allows for significant dose reduction and diagnostic image quality.
出处 《放射学实践》 2014年第9期1003-1007,共5页 Radiologic Practice
关键词 双源双能量CT 肺栓塞 辐射量 图像质量 Dual energy CT Pulmonary embolism Radiation dose Image quality
  • 相关文献

参考文献16

  • 1Ro A, Kageyama N, Tanifui T, et al. Autopsy proven untreated previous pulmonary thromboembolism:frequency and distribution in the pulmonary artery and correlation with patients' clinical characteristics[J]. J Thromb H aemost, 2011,9 ( 5 ) : 922-927.
  • 2路莉,张龙江,卢光明.双源双能量CT在肺栓塞中的应用[J].放射学实践,2011,26(8):899-901. 被引量:6
  • 3Remy-Jardin M,Pistolesi M,Goodman LR, et al. Management of suspected acute pulmonary embolism in the era of CT angiogra phy: a statement from the Fleischner Society [J]. Radiology, 2007,245(2) :315-329.
  • 4Nikolaou K, Thieme S, Sommer W, et al. Diagnosing pulmonary embolism: new computed tomography applications[J]. J Thorac Imaging,2010,25(2) :151-160.
  • 5Zhang LJ, Chai X, Wu SY, et al. Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits [J]. Eur Radiol, 2009, 19 (12) :2844-2854.
  • 6McCollough CH, Primak AN, Braun N, et al. Strategies for reduc- ing radiation dose in CT[J]. Radiol Clin North Am, 2009,47 (1) : 27-40.
  • 7Kang MJ, Park CM, Lee CH, et al. Dual-energy CT : clinical appli- cations in various pulmonary diseases[J]. Radiographics,2010,30 (3) :685-698.
  • 8Li Q,Yu H,Zhang L,et al. Combining low tube voltage and itera- tire reconstruction for contrast-enhanced CT imaging of the chest-Initial clinical experience [ J ]. Clin Radiol, 2013, 68 ( 5 ) : e249-253.
  • 9Hou DJ,Tso DK,Davison C, et al. Clinical utility of ultra high pitch dual source thoracic CT imaging of acute pulmonary embol- ism in the emergency department:are we one step closer towards a non-gated triple rule out[J]. Eur J Radiol,2013,82(10): 1793- 1798.
  • 10Hunsaker AR,Oliva IB,Cai T,et al. Contrast opacification using a reduced volume of iodinated contrast material and low peak Ki- lovoltage in pulmonary CT angiography objective and subjective evaluation[J]. AJR,2010,195(2) : 118-124.

二级参考文献5

共引文献5

同被引文献122

  • 1宋云龙,张挽时,时惠平,毕永民,鲁晓燕,王东.肺栓塞诊断:单层、多层螺旋CT的对比研究[J].医学影像学杂志,2007,17(3):234-237. 被引量:3
  • 2陈爱萍,于红,肖湘生.肺栓塞的影像学研究进展及临床诊断策略[J].国外医学(临床放射学分册),2007,30(5):309-312. 被引量:14
  • 3李杨飞,樊树峰.CT检查中mAs与辐射剂量的比较分析[J].现代中西医结合杂志,2007,16(33):5006-5006. 被引量:9
  • 4Marin D,Boll DT,Mileto A,et al. State of the art:dual energy CT of the abdomen[J]. Radiology,2014,271(2) : 327-342.
  • 5Lu GM,Zhao Y, Zhang LJ, et al. Dual-energy CT of the lung[J]. AJR,2012,199(5 Suppl) ;S40-S53.
  • 6Bauer RW,Kramer S,Renker M,et al. Dose and image quality at CT pulmonary angiography-comparison of first and second genera- tion dual-energy CT and 64-slice CT[J]. Eur Radiol, 2011, 21 (10) :2139-2147.
  • 7Zhang LJ, Wu SY, Niu JB, et al. Dual-energy CT angiography in the evaluation of intracranial aneurysms: image quality, radiation dose, and comparison with 3D rotational digital subtraction angiog- raphy[J]. AJR,2010,194(1) :23-30.
  • 8Morgan DE. Dual energy CT of the abdomen[J]. Abdom Imaging, 2014,39(1) : 108-134.
  • 9Heye T, Nelson RC, Ho LMI ei al. Dual-energy CT applications in the abdomen[J]. AJR,2012,199(5 Suppl) :S64-S70.
  • 10Zhou C, Zhao YE, Luo S,et al. Monoenergetic imaging of dual-en- ergy CT reduces artifacts from implanted metal orthopedic devices in patients with factures[J]. Aead Radiol, 2011, 18 (10) : 1252- 1257.

引证文献13

二级引证文献127

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部