期刊文献+

以CT图像为基础的宫颈癌三维腔内放疗 被引量:23

A clinical study of CT image-based 3D brachytherapy for cervical cancer
原文传递
导出
摘要 目的 探讨CT模拟图像引导下宫颈癌三维腔内放疗实施的可行性及意义.方法 对12例根治性放疗宫颈癌患者的55次腔内施源器置入CT图像,分别设计二维、三维计划,并行配对t检验、Wilcoxon符号秩检验、Pearson相关分析、Spearman相关分析.结果 三维计划双侧A点剂量、D90、V100、CI、CI’均高于二维(P =0.015、0.016、0.000、0.000、0.000),三维计划的膀胱、直肠点剂量及直肠D2cm3略高于二维计划,但热点剂量明显减少.两组计划的膀胱、乙状结肠、小肠D2cm3相近(P=0.140、0.123、0.214).膀胱D2cm3明显高于膀胱点剂量(P =0.000).乙状结肠D2cm3较直肠D2cm3与直肠最高3点剂量平均值更相关(r =0.314、0.63,P=0.000、0.000).V100与高危CTV体积呈线性关系(r =0.981,P=0.000).膀胱D2cm3在膀胱体积>80 cm3后达430 cGy以上,小肠D2cm3在膀胱体积< 115 cm3内变化不明显,一旦超过明显下降.结论 CT引导下宫颈癌三维腔内放疗较传统二维腔内放疗显著增加了靶区覆盖率、提高了适形度,但未明显增加OAR剂量且能及时发现减少OAR热点剂量.点剂量评估并不准确.可以通过膀胱体积调控膀胱、直肠、小肠剂量. Objective To evaluate the feasibility and significance of CT image-based threedimensional (3D) brachytherapy for cervical cancer.Methods Three-dimensional (3D) plan and twodimensional (2D) plan were designed for 55 CT images of brachytherapy from 12 cervical cancer patients who received radical radiotherapy in 2013.Dosimetric comparison was performed between the 3D plan and 2D plan,and paired t-test,Wilcoxon signed rank test,Pearson correlation analysis,and Spearman correlation analysis were performed.Results A point dose,D90,V100,CI,and CI' in 3D plan were higher than those in 2D plan (P=0.015,0.016,0.000,0.000,0.000).Bladder point dose,rectal point dose,and rectal D2 cm3 in 3D plan were slightly higher than those in 2D plan,but hot spot dose was significantly reduced in 3D plan (P =0.140,0.123,0.214).Bladder D2cm3 was significantly higher than bladder point dose (P =0.000).Sigmoid colon D2cm3 was more correlated with the average doses of the three highest rectal points than rectal D2 cm3 (r =0.314,0.630,P =0.000,0.000).V100 showed a linear relationship with high-risk CTV (r =0.981,P =0.000).Bladder D2cm3 was higher than 430 cGy when the bladder volume was more than 80 cm3 ;small intestinal D2 cm3 did not change significantly when the bladder volume was less than 115 cm3,but decreased significantly once the volume exceeded the value.Conclusions Compared with the traditional 2D plan,the 3D plan for CT image-based cervical cancer brachytherapy significantly increases the target coverage and conformity index,but does not significantly increase the doses to organs at risk.Point dose evaluation is confirmed to be inaccurate.The doses to the bladder,rectum,and small intestine can be adjusted by controlling the bladder volume.
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2014年第5期377-381,共5页 Chinese Journal of Radiation Oncology
关键词 宫颈肿瘤/近距离疗法 近距离疗法 三维 剂量体积参数 Cervical neoplasms/brachtherapy Brachtherapy,three-dimensional dose-volume parameters
  • 相关文献

参考文献14

  • 1P(o)tter R,Georg P,Dimopoulos JC,et al.Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D confonnal radiotherapy with or without chemtherpay in patients with locally adavanced cervical cancer[J].Radiother Oncol,2011,100:116-123.
  • 2Haie-Meder C,P(o)tter R,Van Limbergen E,et al.Gynaecological (GYN) GEC-ESTRO working group recommendations from gynaecological (GYN) GEC-ESTRO working group (Ⅰ):concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV[J].Radiother Oncol,2005,74:235-245.
  • 3Viswanathan AN,Dimopoulos J,Kirisits C,et al.Computed tomography versus magnetic resonance imaging-based contouring in cervical cancer brachytherapy:results of a prospective trial and preliminary guidelines for standardized contours[J].Int J Radiat Oncol Biol Phys,2007,68:491-498.
  • 4Viswanathan AN,Erickson BA.Three-dimensional imaging in gynecologic brachtherapy:a survey of the American brachytherapy society[J].Int J Radiat Oncol Biol Phys,2009,76:106-109.
  • 5Pavamani S,D' Souza DP,Portelance L,et al.Image-guided brachytherapy for cervical cancer:a Canadian Brachytherapy Group survey[J].Brachytherapy,2011,10:345-351.
  • 6Petri(o) P,Hudej R,Rogelj P,et al.Uncertainties of target volume delineation in MRI guided adaptive brachytherapy of cervix cancer:a multi-institutional study[J].Radiother Oncol,2013,107:6-12.
  • 7Tan LT,Coles CE,Hart C,et al.Clinical impact of computed tomography-based image-guided brachytherapy for cervix cancer using the tandem-ring applicator-the addenbmoke's experience[J].Clin Oncol,2009,21:175-182.
  • 8Hegazy N,P(o)tter R,Krisits C,et al.High-risk clinical target volume delineation in CT-guided cervical cancer brachytherapy:impact of information from FIGO stage with or without systematic inclusion of 3D documentation of clinical gynecological examination[J].Acta Oncol,2013,52:1345-1352.
  • 9Dolezel M,Odrazka K,Zizka J,et al.MRI-based preplanning using CT and MRI data fusion in patients with cenical cancer treated with 3D-based brachytherapy:feesibility and accuracy study[J].Int J Radiat Oncol Biol Phys,2012,84:146-152.
  • 10Shin KH,Kim TH,Cho JK,et al.CT-guided intracavitary radiotherapy for cervical cancer:comparison of conventional point A plan with clinical target volume-based three-dimensional plan using dose-volume parameters[J].Int J Radiat Oncol Biol Phys,2006,64:197-204.

同被引文献142

  • 1刘文欣,李文录.63例40岁以下浸润性宫颈癌的临床与预后分析[J].中国肿瘤临床,2004,31(19):1101-1105. 被引量:15
  • 2顾保磊.VC++与Access连接及其简单操作的实现[J].武汉工业学院学报,2006,25(1):22-25. 被引量:9
  • 3宋玉春,许伦辉,刘瑶.安装制作工具Inno Setup及其在VC++工程中的应用[J].韶关学院学报,2006,27(6):25-27. 被引量:3
  • 4玛依努尔,李丽,阿也提.昆多孜,张海萌,杨洁,阿依古丽,唐杰.^(252)Cf中子腔内后装加盆腔外照射治疗宫颈鳞癌65例临床对照分析[J].中国实用妇科与产科杂志,2007,23(6):439-441. 被引量:3
  • 5Dimopoulos JC, Kirisits C, Petric P,et al. The Vienna applicator for combined interstitial brachytherapy of cervical canncer:clinical feasibility and preliminary results [J]. Int J Radiat Oncol Biol Phys ,2006,66( 1 ) :83-90.
  • 6Haie-Meder C, Ptter R, Van Limbergen E, et al. Recommenda- tions from gynaecological (GYN) GEC-ESTRO working group (I) :concepts and terms in 3D image based 3D treatment planning in cervix cancer braehytherapy with emphasis on MRI assessment of GTV and CTV [ J ]. Radiuther Oncol,2005,74 ( 3 ) :235-245.
  • 7Ptitter R, Haie-Meder C, Van Limbergen E, et al. Recommenda- tions from gynaecolagieal (GYN) GEC ESTRO working group ( 11 ):eoncepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and as- pects of 3D image-based anatomy, radiation physics, adiobiology [ J]. Radiother 0ncol,2006,78 ( 1 ) :67-77.
  • 8Wakatsuki M, Ohno T, Yoshida D, et al. Intracavitary combined with CT-guided interstitial brachytherapy for locally advanced uter- ine cervical cancer:introduction of the technique and a case pres- entation [ J]. Radiat Res,2011,52 ( 1 ) :54-58.
  • 9Sharma DN, Subramani V, Rath GK, et al. Interstitial braehytreapy guided intensity modulated radiation therapy in cervical carcinoma: a dosimictirc study [J]. Int J Radiat Oncol Bid Phys, 1998,40 (2) :421-426.
  • 10Nomden CN, de Leeuw AA, Mocrland MA, et at. Clinical use of the utrecht applicator for combined intracavitary/interstitial brachy- therapy treatment in locally advanced cervical cancer [ J]. Int J Radiat Oneol Biol Phys,2012,82 (4) : 1424-1430. DOI : 10. 1016/ j. ijrobp. 2011.04. 044.

引证文献23

二级引证文献121