制冷装置综合试验室的研制

Development of the Comprehensive Laboratory for Refrigeration Equipment
下载PDF
导出
摘要 参考国家标准GB/T 7725—2004和相关国际标准ANSI/ARI210/240、ASHRAE37等的技术规范要求,研制一套可测试最大容量为5HP房间空调器的空气焓值法试验室;同时依据冰箱测试标准ANSI/AHAMHRF-1、GB/T 8059.1-4等增加冰箱测试台。同时建有一套恒温冷热水系统,用来检测水冷柜机、风机盘管、空气源热泵热水器等产品。试验室要求空调器在进行季节能效比测试时,完成对Cd系数的准确测定,因此在常规试验室基础上改进风量接收箱,增加吸入风门箱。制冷装置综合试验室能够模拟制冷装置实际运行环境,从而对相关制冷产品的各项工作参数进行测定。 Having referred to the technical specification of both the National Standard GB/T 7725-- 2004 and the relevant international standards ANSI/ARI 210/240 and ASHRAE37, a set of air-enthalpy method laboratory which can test the room air conditioner with the maximum capacity of 5HP is developed; at the same time, refrigerator test-bed was added to the comprehensive laboratory according to the refrigerator test standard ANSI/AHAM HRF-1, GB/T 8059.1-4. Also a set of constant temperature cold-hot water system was designed when testing the products such as water-cooled chiller units, fan coil units, air source heat pump water heater. Based on?conventional air enthalpy method, laboratory improved airflow receiving case, added the suction case, thus can test the Cd coefficient accurately when testing the Seasonal Energy Efficiency Ratio. The actual operation environment of the refrigeration equipment can be simulated in the comprehensive laboratory, and the relevant refrigeration sured. equipment performance parameters can be measured.
出处 《建筑节能》 CAS 2014年第9期6-12,共7页 BUILDING ENERGY EFFICIENCY
关键词 空气焓值法试验室 冰箱测试台 恒温冷热水系统 Cd系数 air enthalpy laboratory refrigerator test-bed constant temperature cold-hot water system Cd coefficient
  • 相关文献

参考文献10

二级参考文献23

  • 1段雪涛,邬志敏,王芳,黄超,杜世春.基于PID控制的4工位冰箱性能测试试验室研制[J].上海理工大学学报,2005,27(4):327-330. 被引量:5
  • 2ANSI/ARI Standard 210/240-2008 Unitary Air-Conditioning and Air-Source Heat Pump Equipment.
  • 3Brian P Dougherty, James J Filliben, Ana Ivelisse Aviles. Central Air Conditioner Test Procedure Public Workshop: A Technical Discussion On New Defaults for National Institute of Standards and Technology Gaithersburg, MD 20899.
  • 4Goldsehmidt V W, Hart G H, Reiner R C. A note on the transient performance and degradation coefficient of a field heat pump cooling mode. ASHRAE Transactions, 1980, 86(2) :368-375.
  • 5ANSI ( American National Standards Institute ), AHRI (The Air- Conditioning, Heating, and Refrigeration Institute) .ANSI/AHRI Standard 210/240- 2008 Unitary Air- Conditioning and Air - Source Heat Pump Equipment [ S/ OL] .U.S.A : AHRI (The Air- Conditioning, Heating, and Refrigeration Institute), 2008: 2, 14, 70-73, 89.
  • 6Goldschmidt V.W., Hart G.H., Reiner R. C. A note on the transient performance and degradation eoetficient of a field heat pump cooling mode [ J ] .ASHRAE Transactions, 1980, 86 (2) : 368 - 375.
  • 7GB/T7725-2004.房间空气调节器[S].[S].,..
  • 8郑贤德.制冷原理与装置[M].北京:机械工业出版社,2000.60-61.
  • 9国家标准委员会.GB/T 8059.2-95,家用制冷器具冷藏冷冻箱[S].北京:中国标准出版社,1995..