摘要
介绍了300 MW机组锅炉低氮燃烧器改造情况,改造后锅炉NOx排放值从改造前的1 000 mg/m3左右降低到400 mg/m3左右,降低氮氧化物幅度在60%以上,减轻了脱硝装置的压力,达到了优化设计、优化运行的目的,并对低氮燃烧器改造后锅炉再热汽温偏低的情况进行了分析和研究。
Technical innovation of the low NOx burner in a 300 MW unit is introduced. With the innovation,a reduction more than 60% in the NOx emission is observed,as the emission value drops from 1 000 mg /m^3 to 400 mg /m^3. The investment and operation cost of denitration device is then reduced. Furthermore,the influence of this innovation on the reheated stream temperature is also analyzed.
出处
《水电与新能源》
2014年第9期75-78,共4页
Hydropower and New Energy
关键词
锅炉
低氮燃烧器
NOx
燃尽风
再热汽温
boiler
low NOx burner
NOx
burnout air
reheated steam temperature