长距离输水管线中空气阀和单向调压塔联合作用的水锤防护研究 被引量:7

Research on water hammer protection of long-distance pipelines with the combination of one-way surge tank and air valve
原文传递
导出
摘要 在长距离输水管线中,当事故停泵时,管路会产生负压,甚至出现汽化和液注分离,如果不采取合理的防护措施会导致管线的破坏。根据气液两相水锤计算模型,结合某长距离输水工程水力过渡过程数值模拟计算,利用空气阀和单向调压塔联合作用,并配合泵后阀门2阶段关闭的防护技术,有效地控制了管线的水锤压力。 In long-distance water pipelines, the negative pressure, even column separation, easily happen when the pump power outages due to an accident. If there are no reasonable protective measures in the system, the waterhammer will lead to the destruction of the pipeline. Based on the air-liquid two phase water hammer model.By the hydraulic transient calculation of practical long- distance watersupply project, the paper present that the combination of air valve and one-way surge tank with valve two stage closed can solve the Pump-stopping water hummer.
出处 《北京水务》 2014年第5期42-45,共4页 Beijing Water
基金 国家自然科学基金(51279145)
关键词 水锤防护 空气阀 单向调压塔 关阀 长距离输水管线 water hammer protection air valve one-way surge tank long-distance water-supplypipelines