期刊文献+

腹部动脉能谱CT混合能量与单能量图像的比较研究 被引量:9

Comparative Study of Polychromatic and Monochromatic Images of Abdominal Artery with Spectral CT Imaging
下载PDF
导出
摘要 目的通过比较腹部动脉能谱CT成像中混合能量重建模式图像与单能量重建模式图像的质量,筛选适宜观察腹部动脉的图像重建模式。方法 80例患者采用GE公司的宝石CT能谱成像技术,获得腹部动脉混合能量图像(140kVp)和40-140keV范围内的单能量图像。对混合能量图像和单能量图像进行感兴趣区CT值的测量,计算腹主动脉、肝动脉的SNR和CNR;各组图像由三名有经验的放射医师采用盲法进行图像质量主观评分。最后进行腹部动脉CT值、SNR、CNR和图像质量主观评分的综合比较。所获数据采用SPSS 19.0软件进行统计学分析。结果随着keV值的降低,腹部动脉CT值逐渐升高,图像噪声同时发生改变。根据腹部动脉图像质量的客观指标(CT值、SNR和CNR)和主观评分,对混合能量图像与各组单能量图像进行综合比较,结果显示50-60keV单能量组腹部动脉图像质量优于混合能量组,同时单能量成像对腹主动脉和肝动脉图像质量的影响存在差别。结论在腹部能谱CT常规增强扫描所获得的腹部动脉不同类型重建图像中,50-60keV单能量重建模式的图像质量优于混合能量重建模式,推荐其作为腹部动脉能谱CT扫描的常规重建模式。 Objective To evaluate the difference of polychromatic and monochromatic images reconstruction mode in abdominal artery with Spectral CT imaging, choose the appropriate reconstruction mode for the best displaying of abdominal artery. Methods Abdomen enhanced CT scans were applied with spectral imaging technique (Discovery CT750 HD, GE Healthcare) on eighty patients, and got the polychromatic images(140kVp) and monochromatic images ranged from 40 to 140 keV of abdominal artery. CT value measurements of ROIs were performed in the polychromatic and monochromatic images, then the SNR and CNR of abdominal aorta and hepatic artery were calculated. Three experienced radiologists evaluated subjective image quality of the images in all groups. The following variables of abdominal artery were compared together: CT value, SNR, CNR and subjective ratings. Statistical analysis of all data were accomplished with SPSS 19.0 soft package. Results The CT value of abdominal artery increased gradually with the decrease of keV, image noise changed at the same time. The image quality of 50-60 keV monochromatic images are better than polychromatic images by comparing all variables(CT value, SNR, CNR and subjective ratings) of them, there is something difference of monochromatic images between abdominal aorta and hepatic artery. Conclusion In abdominal spectral CT imaging with enhenced CT scan, 50-60 keV monochromatic reconstruction can provide better quality images, it was recommended as the conventional reconstruction mode of abdominal artery spectral CT scan.
出处 《中国CT和MRI杂志》 2014年第8期91-94,共4页 Chinese Journal of CT and MRI
基金 2012年度汕头市医疗重点科技计划项目(项目编号:汕府科[2012]113号)
关键词 腹部 体层摄影扫描仪 x线计算机 能谱成像 CT血管成像 重建模式 Abdomen Computed Tomography Scanner, X-Ray Spectral CT Imaging CT Angiography Reconstruction Mode
  • 相关文献

参考文献8

  • 1Wu X, Langan I)A, Xu D, et al. Monochromatic CT imagerepresentation via fast switching dual kVp[J] .SPIE Medical Imaging. International Society for Optics and Photonics, 2009: 725845- 725845-9.
  • 2Zhao L, He W, Li J, et al. Improving image quality in portal venography with spectral Cr imaging[J]. European journal of radiology, 2012, 81(8): 1677-1681.
  • 3Lin X Z, Miao F, Li J Y, et al. High-definition CT Gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction[J] . Journal of computer assisted tomography, 2011, 35(2): 294- 297.
  • 4Graser A, Johnson TR, Bader M , et al . Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience[J]. Invest Radiol 2008 ; 43 (2):112-119.
  • 5Lv P, Lin X Z, Li J, et al. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: recently introduced spectral CT method[J].Radiology, 2011, 259(3): 720-729.
  • 6黄蓉,顾建平,殷信道,楼文胜,何旭,陈亮,陈国平.新双源CT在下肢动脉阻塞性疾病中的临床应用[J].中国CT和MRI杂志,2013,11(2):101-105. 被引量:21
  • 7张晓鹏.探索的精神与乐趣——CT能谱成像临床应用研究中的思考[J].中华放射学杂志,2011,45(8):709-712. 被引量:71
  • 8李小虎,刘斌,余永强,王明明,王万勤,张帅,张艺飞,吴兴旺,陈垦,周勇,王乐.能谱CT单能量区分体外肾结石成分的初步实验研究[J].中国CT和MRI杂志,2011,9(5):9-11. 被引量:27

二级参考文献22

  • 1邓穗平,陈德志,欧阳健明.泌尿系结石组分分析方法及其研究进展[J].光谱学与光谱分析,2006,26(4):761-767. 被引量:23
  • 2Cui Y, Zhang XP. Evaluation of normal pancreatic duct: a comparison between discovery CT750 HD and 64-section multidectector CT ( control number: C-1811 ) [ C/OL ]//European Congress of Radiology, Vienna, 2011 [ 2010-09-20 ] . http:// www. myesr, org/cms/.
  • 3Tang L, Zhang XP. Quantitative evaluation of perigastric fat infiltration by gastric cancer: initial experience with spectral CT imaging ( control number: C-0759 ) [ C/OL ]//European Congress of Radiology, Vienna, 2011 [ 2010-09-20 ] . http:// www. myesr, org/ems/.
  • 4Cui Y, Zhang XP. Evaluation of different reconstruction mode images on abdomen spectral CT imaging (control number: C- 0802 ) [ C/OL ]//European Congress of Radiology, Vienna, 2011 [2010-09-20]. http://www, myesr, org/cms/.
  • 5Li Y, Zhang XP. Selecting optimal monochromatic level in spectral imaging for CT hepatic artery angiography and portal venography with standard concentration and dose of contrast medium ( control number: C-1870) [ C/OL]//European Congress of Radiology, Vienna,2011 [ 2010-09-20 ]. http ://www. myesr, org/cms/.
  • 6Li YL, Zhang XP. Application of effective-Z in spectral CT imaging: an initial study (control number: C-1440) [ C/OL]// European Congress of Radiology, Vienna, 2011 [ 2010-09-20 ]. http ://www. myesr, org/cms/.
  • 7Hu Y, Zhang XP. Characteristic spectral curve of normal adrenal gland on energy spectral CT ( control number: C-1507 ) [ C/ OL]//European Congress of Radiology, Vienna, 2011 [ 2010-09- 20]. http://www, myesr, org/cms/.
  • 8Sun YS, Zhang XP. Spectral CT imaging as a new quantitative tool? Assess the contrast material distribution of the pulmonary parenchyma in patients with tung cancer (control number: C- 0840) [ C/OL]//European Congress of Radiology, Vienna,2011 [ 2010-09-20 ]. http ://www. myesr, org,/cms/.
  • 9Zhang XY, Zhang XP. Spectral CT characterisation of thyroid solitary node : a pilot study (control number: B-816) [ C/OL]// European Congress of Radiology, Vienna, 2011 [ 2010-09-20 ]. http://www, myesr, org/cms/.
  • 10Wang ZL, Zhang XP. A new perspeetive understanding of gastric cancer: the spectral HU curve of gemstone CT spectral imaging (control number: C-1831 ) [ C/OL]//European Congress of Radiology, Vienna, 2011 [ 2010-09-20 ]. http ://www. myesr, org/ cms//.

共引文献115

同被引文献79

  • 1兰永树,黄文龙,朱德强,唐光才.影响CT值测量的因素及对策的探讨[J].实用放射学杂志,2006,22(3):352-355. 被引量:27
  • 2Chiro GD, Brooks RA, Kessler RM, et al. Tissue signatures with dual-energy computed tomography[J]. Radiology, 1979, 131(2): 521-523.
  • 3Graser A, Johnson TR, Bader M, et al. Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience[J]. Investigative Radiology, 2008, 43(2): i12-I19.
  • 4Zhang D, Li X, Liu B. Objective characterization of GE discover CT750 HD scanner: Gemstone spectral imaging mode[J]. Medical Physics, 2011, 38(3): 1178-1188.
  • 5Ho LM, Yoshizumi TT, Hurwitz LM, et al. Dual energy versus single energy MDCT: Measurement of radiation dose using adult abdominal imaging protocols[J]. Academic Radiology, 2009, 16(11): 1400-1407.
  • 6Holmes DR, Fletcher JG, Anja A, et al. Evaluation of nonlinear blending in dual-energy computed tomography[J]. European Journal of Radiology, 2008, 68(3): 409- 413.
  • 7Lv P, Lin XZ, Li J. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: Recently introduced spectral CT method[J]. Radiology, 2011, 259(3): 720-729.
  • 8Graser A, Johnson TR, Chandarana H, et al. Dual energy CT: Preliminary observations and potential clinical applications in the abdomen. Eur Radiol, 2009,19(1):15-23.
  • 9Saba L, Sanfilippo R, Anzidei M, et al. Comparison between postprocessing techniques in the analysis of hepatic arteries using multi-detector-row computed tomography angiography. J Comput Assist Tomogr, 2011,35(2) :174-180.
  • 10Ichikawa T, Motosugi U, Morisaka H, et al. Optimal Iodine dose for 3-dimensional multidetector-row CT angiography of the liver. Eur J Radiol, 2012,81(9):2450-2455.

引证文献9

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部