摘要
建立了液相色谱-串联质谱法同时测定犬血浆中的替格瑞洛(1)及其主要活性代谢产物AR-C124910XX (2).使用C18色谱柱,以乙腈∶2 mmol/L乙酸铵溶液(70∶30)为流动相,地西泮为内标,采用TQ-MS检测器,电喷雾离子源(ESI),以正离子多反应监测(MRM)方式进行定量分析,监测离子对m/z 523.3→m/z 127.1 (1)、m/z 479.3→m/z 153.1 (2)和m/z 284.9→m/z 193.0(内标).1、2均在50~10 000 ng/ml范围内线性关系良好;提取回收率为109.8%~ 115.1%和109.3%~114.5%,日内RSD≤6.8%,日间RSD≤14.2%.
A LC-MS/MS method was established for the determination ofticagrelor (1) and its active metabolite AR-C124910XX (2) in dog plasma with diazepam as the internal standard.A C18 column was used,with the mobile phase of acetonitrile ∶ 2 mmol/L ammonium acetate solution (70 ∶ 30).An electrospray ionization source (ESI) was operated in positive ion mode and multiple reaction monitoring (MRM) mode with the transitions of m/z 523.3→m/z 127.1 (1),m/z 479.3→m/z 153.1 (2) and m/z 284.9→m/z 193.0 (diazepam),respectively.It was linear for 1 and 2 in the range of 50-10 000 ng/ml.Their extraction recoveries were 109.8%-115.1% and 109.3%-114.5%,with the intra-day RSDs no more than 6.8 % and inter-day RSDs no more than 14.2 %.